Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALABAMA CULLMAN YUTAKA TECHNOLOGIES LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALABAMA CULLMAN YUTAKA TECHNOLOGIES LLC in 460 AL HIGHWAY 157, CULLMAN, AL 35058 (NAICS 336390). OSHA activity number 343343323.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alabama Cullman Yutaka Technologies LLC — free Get an email when a new federal OSHA severe-injury report for Alabama Cullman Yutaka Technologies LLC is published. One employer, no account, unsubscribe in one click.
Site address
460 AL HIGHWAY 157
City
CULLMAN
State
AL
ZIP
35058
Mailing
460 AL HIGHWAY 157, CULLMAN, AL 35058
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336390
Employees
450
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 28, 2018
Penalty
Initial $9,424 · Current $6,126 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) On or about 7/20/2018 - Clean Room Staging Area, a procedure was not developed, documented, and utilized for the control of hazardous energy when employees were troubleshooting and servicing the Micanan medium duty jackshaft operator exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $6125.6
  • — Z (S) $9424

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 28, 2018
Penalty
Initial $9,423 · Current $6,125 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a) On or about 7/20/2018 - Clean Room Staging Area, the pulley for the outer roll-up door was not guarded.
Recent events (2)
  • — I (S) $6124.95
  • — Z (S) $9423

1910.219 E03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  (a) On or about 7/20/2018 - Clean Room Staging Area, the belt for the outer roll-up door was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J04 VI

Other-than-serious 1 instance 2 exposed
Issued
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(4)(vi): Individual disconnecting means were not provided for each motor:  (a) On or about 7/20/2018 - Clean Room Staging Area, the Micanan operator motor for the outer door did not have an individual disconnecting means.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Alabama Cullman Yutaka Technologies LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343343323.