Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIR NATIONAL GUARD

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AIR NATIONAL GUARD in 168TH MAINTENANCE GROUP 375 TANKER ROAD, EIELSON AFB, AK 99702 (NAICS 488190). OSHA activity number 343343455.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR National Guard — free Get an email when a new federal OSHA severe-injury report for AIR National Guard is published. One employer, no account, unsubscribe in one click.
Establishment
AIR NATIONAL GUARD
Site address
168TH MAINTENANCE GROUP 375 TANKER ROAD
City
EIELSON AFB
State
AK
ZIP
99702
Mailing
354 BROADWAY AVENUE, EIELSON AFB, AK 99702
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488190
Employees
800
Ownership type
D

2 citations on file for this inspection.

1910.22 A03

Serious Gravity 5 1 instance 7 exposed
Issued
Aug 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(3): Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice:  Phase Dock:  On or about July 25, 2018 and at times prior thereto, a slippery petroleum substance was allowed to spill on the walking surface of the hangar floor.  This condition exposed employees to slip hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 I01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 27, 2018
Abate by
Nov 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(i)(1)(ii): Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989:    Sheet Metal Shop:  On or about July 25, 2018 and at times prior thereto, the employer could not confirm that breathing air for supplied-air respiratory protection could meet Grade D requirements.  This condition exposed employees to inhalation hazards in the event of inadequate supplied breathing air.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View AIR National Guard's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343343455.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.