UNIONTOWN, PA —
OSHA Inspection: MONRO MUFFLER AND BRAKE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MONRO MUFFLER AND BRAKE, INC. in 272 MCCLELLANDTOWN ROAD, UNIONTOWN, PA 15401 (NAICS 811111). OSHA activity number 343346789.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONRO MUFFLER AND BRAKE, INC.
- Site address
- 272 MCCLELLANDTOWN ROAD
- City
- UNIONTOWN
- State
- PA
- ZIP
- 15401
- Mailing
- 272 MCCLELLANDTOWN ROAD, UNIONTOWN, PA 15401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 G02 I
- Issued
- Sep 11, 2018
- Penalty
- Initial $11,087 · Current $11,087
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures, or by any of the following means identified in sub-paragraphs (A)through (D) of this paragraph: (a) Facility- 272 McClellandtown Road, Uniontown, PA: Employees were exposed to live wires from the exhaust fan; an employee was electrically shocked when coming in contact with the wires.
Recent events (1)
- — Z (S) $11087
1910.332 B01
- Issued
- Sep 11, 2018
- Abate by
- Oct 5, 2018
- Penalty
- Initial $5,543 · Current $5,543
General-duty citation text
29 CFR 1910.332(b)(1): Employees had not been trained and made familiar with the safety related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments. (a) Facility- 272 McClellandtown Road, Uniontown, PA: On or about August 1, 2018, technicians that were working on electrical equipment were not trained on electrical work safe practices.
Recent events (1)
- — Z (S) $5543
More inspections at Monro Muffler and Brake, INC.
View Monro Muffler and Brake, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343346789.