TUCSON, AZ —
OSHA Inspection: U.S. CUSTOMS AND BORDER PROTECTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. CUSTOMS AND BORDER PROTECTION in U.S. BORDER PATROL-TUCSON SECTOR 2430 S. SWAN ROAD, TUCSON, AZ 85711 (NAICS 928110). OSHA activity number 343351383.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. CUSTOMS AND BORDER PROTECTION
- Site address
- U.S. BORDER PATROL-TUCSON SECTOR 2430 S. SWAN ROAD
- City
- TUCSON
- State
- AZ
- ZIP
- 85711
- Mailing
- U.S. BORDER PATROL-TUCSON SECTOR 2430 S. SWAN ROAD, TUCSON, AZ 85711
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 443
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.159 C10
- Issued
- Sep 28, 2018
- Abate by
- Oct 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems sprinklers and the material below was not maintained: The minimum vertical clearance between the automatic sprinkler system and the material below was not maintained. Employees stacked boxes of materials on metal shelving in a matter which did not allow for 18 inch clearance. a) Room 1022 - Materials were stored approximately 9 inches from sprinkler heads. b) Room 1066 - Cardboard boxes were stored approximately 9 inches from sprinkler heads. c) Room 1068 - Printer Cartridges stored approximately 6 inches from sprinkler heads. d) Room 1108 - Flammable containers and boxes stored approximately 3 inches from sprinkler heads.
Recent events (1)
- — Z (S) $0
1910.213 H04
- Issued
- Sep 28, 2018
- Abate by
- Oct 4, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: Shop - The Delta Radial Arm saw did not return gently to the starting position when released by the operator.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Sep 28, 2018
- Abate by
- Oct 4, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Garage - A Balder double wheeled bench grinder had measured gaps of 1" on the left side between the tongue guard and the abrasive wheel.
Recent events (1)
- — Z (S) $0
1910.252 B02 III
- Issued
- Sep 28, 2018
- Abate by
- Oct 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: Welding Shop - Employees who walked and worked in areas adjacent to welding operations, were not protected from ultraviolet radiation by welding screens or shields or by wearing appropriate goggles.
Recent events (1)
- — Z (S) $0
1910.253 B04 III
- Issued
- Sep 28, 2018
- Abate by
- Oct 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: Welding Shop Outside - Welding gases Oxygen and Acetylene were stored within a distance of approximately 6-feet from each other.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Sep 28, 2018
- Abate by
- Oct 4, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Room 1121 - A "UL" listed relocatable power tap (RPT) was not used in accordance with instructions to power a 3.5 cubic foot refrigerator.
Recent events (1)
- — Z (S) $0
More inspections at U.S. Customs and Border Protection
View U.S. Customs and Border Protection's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343351383.