Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PVT TRUCK AND TRAILER REPAIR LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PVT TRUCK AND TRAILER REPAIR LLC in 593 MALE ROAD, WIND GAP, PA 18091 (NAICS 811111). OSHA activity number 343381760.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PVT Truck and Trailer Repair LLC — free Get an email when a new federal OSHA severe-injury report for PVT Truck and Trailer Repair LLC is published. One employer, no account, unsubscribe in one click.
Site address
593 MALE ROAD
City
WIND GAP
State
PA
ZIP
18091
Mailing
593 MALE ROAD, WIND GAP, PA 18091
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
12
Ownership type
A

2 citations on file for this inspection.

1910.28 B08 II

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 17, 2018
Abate by
Oct 1, 2018
Penalty
Initial $3,696 · Current $1,847 Reduced
29 CFR 1910.28(b)(8)(ii): For a repair pit, service pit, or assembly pit that was less than 10 feet (3 m) deep, the employer did not apply floor markings at least 6 feet (1.8 m) from the edge of the pit in colors that contrast with the surrounding area; or place a warning line at least 6 feet (1.8 m) from the edge of the pit as well as stanchions that are capable of resisting, without tipping over, a force of at least 16 pounds (71 N) applied horizontally against the stanchion at a height of 30 inches (76 cm); or place a combination of floor markings and warning lines at least 6 feet (1.8 m) from the edge of the pit.      a)  Pit - On or about August 9, 2018, the employer did not ensure that stanchions with a warning line were put into place at least six feet from the edge of the approximately four foot deep service pit.
Recent events (2)
  • — I (S) $1847
  • — Z (S) $3696

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 17, 2018
Abate by
Oct 22, 2018
Penalty
Initial $3,696 · Current $1,848 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a)  Worksite - On or about August 9, 2018, employees are performing maintenance on equipment with multiple sources of energy to include, but not limited to, electrical and hydraulic sources, but the employer did not develop an energy control program with specific procedures, employee training and periodic inspection for the workplace.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

View PVT Truck and Trailer Repair LLC's full OSHA safety record →