Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CMG PROCESS, INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CMG PROCESS, INC in 2659 LAKE ROAD, CLARK, PA 16113 (NAICS 339999). OSHA activity number 343428629.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CMG Process, INC — free Get an email when a new federal OSHA severe-injury report for CMG Process, INC is published. One employer, no account, unsubscribe in one click.
Establishment
CMG PROCESS, INC
Site address
2659 LAKE ROAD
City
CLARK
State
PA
ZIP
16113
Mailing
2659 LAKE ROAD, CLARK, PA 16113
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339999
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 26, 2018
Abate by
Nov 14, 2018
Penalty
Initial $1,885 · Current $1,400 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before use of the respirator in the workplace:          a.)  CMG Process, Inc. dba Apex Engineered Products, Shop areas, on or about August 29th,2018 and times prior thereto:  Employees were voluntarily wearing elastomeric half mask, air purifying respirators (Honeywell North brand #7190 with N99 filters) during welding operations at the facility.  Employees were not provided with a medical evaluation prior to the use of the respirators onsite.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $1885

1910.134 C01

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 26, 2018
Abate by
Nov 14, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): The respiratory protection program was not updated as necessary to reflect those changes in workplace conditions that affected respirator use:    a.)  CMG Process, Inc. dba Apex Engineered Products, shop areas, on or about August 29th,2018 and times prior thereto:  Employees were voluntarily wearing half mask elastomeric, air purifying respirators (Honeywell North brand #7190 with N99 filters) during welding operations at the facility.      The company's written respiratory protection program did not include updated site specific information including, but not limited to, the following:    1) The program did not describe the types of respirators that were available to employees.       2) Identification of the physician or other licensed health care professional that will conduct medical evaluations.     3) Information regarding the requirement to provide medical evaluations for employees who don half mask elastomeric respirators voluntarily.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K06

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 26, 2018
Abate by
Oct 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:    a.) CMG Process, Inc. dba Apex Engineered Products, shop areas, on or about August 29th,2018 and times prior thereto:  Employees were voluntarily wearing half mask elastomeric, air purifying respirators (Honeywell North brand #7190 with N99 filters) during welding operations at the facility.  Employees were not provided with the information in Appendix D to this section.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E02 IV D

Serious Gravity 5 1 instance 18 exposed
Issued
Sep 26, 2018
Penalty
Initial $2,136 · Current $1,400 Reduced
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve:           a)  CMG Process, Inc. dba Apex Engineered Products, West wall of "lower shop area", On or about August 29th, 2018 and times prior thereto:  Employees were dispensing a category 2 flammable liquid (acetone) into secondary containers in order to clean metal parts.  The dispensing valve for the flammable liquid was not self-closing.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2136

1910.106 E06 I

Serious Gravity 5 1 instance 18 exposed
Issued
Sep 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:    a)  CMG Process, Inc. dba Apex Engineered Products, West wall of "lower shop area", On or about August 29th, 2018 and times prior thereto:  Employees were dispensing a category 2 flammable liquid (acetone) from a 55 gallon drum into secondary containers in order to clean metal parts.  The 55 gallon drum of acetone was not grounded to provide the dissipation of static electricity associated with dispensing the liquid from the drum to smaller containers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E06 II

Serious Gravity 5 1 instance 18 exposed
Issued
Sep 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(ii): A Category 2 flammable liquids with a flashpoint below 100 °F (37.8 °C) was dispensed into containers without the nozzle and container electrically interconnected:    a)  CMG Process, Inc. dba Apex Engineered Products, West wall of "lower shop area", On or about August 29th, 2018 and times prior thereto:  Employees were dispensing a category 2 flammable liquid (acetone) from a 55 gallon drum into secondary containers in order to clean metal parts.  The metal drum was not bonded to the smaller containers, during transfer, to provide dissipation of static electricity while dispensing the flammable liquid.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View CMG Process, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343428629.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.