LUMBER CITY, GA —
OSHA Inspection: TELFAIR FOREST PRODUCTS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TELFAIR FOREST PRODUCTS, LLC in 11 WEST INDUSTRIAL BLVD, LUMBER CITY, GA 31549 (NAICS 321113). OSHA activity number 343432365.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TELFAIR FOREST PRODUCTS, LLC
- Site address
- 11 WEST INDUSTRIAL BLVD
- City
- LUMBER CITY
- State
- GA
- ZIP
- 31549
- Mailing
- 11 WEST INDUSTRIAL BLVD., LUMBER CITY, GA 31549
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 46
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 9, 2019
- Abate by
- Feb 5, 2019
- Penalty
- Initial $9,054 · Current $6,338 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: A) Shaving machine #3, on or about August 20, 2018, or prior to, an employee entered into a shaver box that contained rotating shaving heads, without utilizing the lockout procedures and shutting the shaving heads down and locking the machine out, exposing the employee to an amputation hazard.
Recent events (2)
- — I (S) $6337.8
- — Z (S) $9054
1910.147 C05 I
- Issued
- Jan 9, 2019
- Abate by
- Feb 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: A) Shaving machine #3, on or about August 20, 2018, or prior to, an employee was not provided a lockout device to be used when locking out a shaver box before entering the box to clear a jam, exposing the employee to an amputation hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Telfair Forest Products, LLC
View Telfair Forest Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343432365.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.