SHEBOYGAN, WI —
OSHA Inspection: NEMAK USA, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of NEMAK USA, INC. in 4243 GATEWAY DRIVE, SHEBOYGAN, WI 53081 (NAICS 331523). OSHA activity number 343432910.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEMAK USA, INC.
- Site address
- 4243 GATEWAY DRIVE
- City
- SHEBOYGAN
- State
- WI
- ZIP
- 53081
- Mailing
- 4243 GATEWAY DRIVE, SHEBOYGAN, WI 53081
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331523
- Employees
- 900
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 26, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
R252R278
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards, that were causing or likely to cause death or serious physical harm to employees in that employees working at or near equipment containing metalworking fluids (MWF) were exposed to microbiological material (endotoxins) that caused hypersensitivity pneumonitis, a debilitating lung disease: a) The Dial/Cyclone machine required Durakut 525 metalworking fluid (MWF) for the processing of die cast aluminum work pieces. The metal removing stations, the MWF collection and sump system were unenclosed and open to the department's environment. Bulk samples of MWF collected from the Dial Sump Pit contained up to 92,000 Endotoxin Units (EU)/mL. Air samples collected at the workstation of Dial machine operator(s) indicated the presence of airborne endotoxins at a concentration up to 2,420 EU/m^3 as an 8-hour Time Weighted Average (TWA). b) The Boss Line's consisted of multiple machines, including the Tuff CNC machine and Toyoda 9 machine, which both required Durakut 525 metal working fluid (MWF) for the processing of die cast aluminum work pieces. The MWF collection and sump system of the Tuff CNC machine were unenclosed and open to the department's environment. Bulk samples of MWF collected from the Toyoda 9 machine's main compartment contained up to 1,900 Endotoxin Units (EU)/mL. Bulk samples of MWF collected from the open air sump pit of the Tuff CNC machine contained up to 930 EU/mL. Air samples collected at a workstation between the Boss Line and Dial/Cyclone indicated the presence of airborne endotoxins at a concentration up to 341 EU/m^3 as an 8-hour Time Weighted Average (TWA). Among other methods, some feasible and acceptable means of abatement include, but are not limited to the following: a) Enclose all processes dependent on MWFs (including but not limited to operations on the Dial/Cyclone and Boss Line machines) to minimize aerosolizing of MWF and its biological material. b) Install local exhaust ventilation (LEV) and mist collection systems for capture and control of MWF and its aerosolized biological material. Ensure that a preventive maintenance schedule is implemented, which at a minimum includes daily inspections of the engineering control systems (e.g. magnahelic airflow pressure gauges); checking and changing filters at regularly scheduled intervals specified by the mist collector manufacturer and dependent on production demands. c) Add time-delays on door openings where practicable and leave enclosure doors closed until the LEV clears mist inside the machine, and stop the delivery of MWF when machining has completed.
Recent events (3)
- — F (S) $0
- — C (S) $13260
- — Z (S) $13260
1910.134 D01 III
- Issued
- Feb 26, 2019
- Abate by
- Apr 10, 2020
- Penalty
- Initial $13,260 · Current $9,800 Reduced
R252R278
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH: The employer did not sufficiently evaluate the respiratory hazards in the area immediately surrounding its Dial/Cyclone Machine in the 1600 Ton 2nd Operations department.
Recent events (3)
- — F (S) $9800
- — C (S) $13260
- — Z (S) $13260
More inspections at Nemak USA, INC.
View Nemak USA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331523)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343432910.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.