OSHA Inspection: HARRIS DOOR & DRAWER, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARRIS DOOR & DRAWER, INC. in 5042 BRISTOL INDUSTRIAL WAY, BUFORD, GA 30518 (NAICS 321911). OSHA activity number 343435640.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harris Door & Drawer, INC. — free Get an email when a new federal OSHA severe-injury report for Harris Door & Drawer, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5042 BRISTOL INDUSTRIAL WAY
City
BUFORD
State
GA
ZIP
30518
Mailing
5042 BRISTOL INDUSTRIAL WAY, BUFORD, GA 30518
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
40
Ownership type
A

8 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 4 instances 4 exposed
Issued
Dec 28, 2018
Abate by
Jan 25, 2019
Penalty
Initial $9,054 · Current $5,432 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) On or about 08/30/18 and at times prior thereto employees operated the joiner. The feed area of the machine was not guarded.  b) On or about 08/30/18 and at times prior thereto employees operated the joiner. The discharge area of the machine was not guarded. (The original cover was removed and the conveyor chain was exposed).   c) On or about 08/30/18 and at times prior thereto employees operated the rip saw. The discharge area of the machine was not guarded. (The original cover was removed and the conveyor chain was exposed).   d) On or about 08/30/18 and at times prior thereto the Ritter router Model R20DC, S/N 1002, 240 V, was not guarded.  Or in the alternative:  29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) On or about 08/30/18 and at times prior thereto employees operated the joiner. The feed area of the machine was not guarded.  b) On or about 08/30/18 and at times prior thereto employees operated the joiner. The discharge area of the machine was not guarded. (The original cover was removed and the conveyor chain was exposed).   c) On or about 08/30/18 and at times prior thereto employees operated the rip saw. The discharge area of the machine was not guarded. (The original cover was removed and the conveyor chain was exposed).   d) On or about 08/30/18 and at times prior thereto the Ritter router Model R20DC, S/N 1002, 240 V, was not guarded.  n accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $5432.4
  • — Z (S) $9054

1910.242 B

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 28, 2018
Abate by
Jan 25, 2019
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  a) Plant - On or about  08/30/18 and at times prior thereto employees working in the front of the plant utilized compressed air for cleaning at a nominal pressure of 100 psig.  b) Plant - On or about 08/30/18 and at times prior thereto employees working in the maintenance area  utilized compressed air for cleaning at a nominal pressure of 100 psig.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.303 B07 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 28, 2018
Abate by
Jan 25, 2019
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.303(b)(7)(iv): There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.  a) Plant - On or about 08/30/18 and at times prior thereto employees operated the Ritter router Model R20DC, S/N 1002, 240 V.  The foot switch that activated the pneumatic clamp had a broken strain relief device. The cables and terminals were exposed to damage and loss of insulation.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.303 G01 II

Serious Gravity 5 2 instances 1 exposed
Issued
Dec 28, 2018
Abate by
Jan 25, 2019
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) Plant - The work space for the disconnect boxes mounted on the wall outside the electrical room was obstructed by an aluminum ladder and boxes with materials. The electrical equipment was not readily accessible in case of service or emergency.     b) Plant - On or about 08/30/18 and at times prior thereto the work space for the panel boards mounted inside the electrical room was obstructed  by cable reels  and boxes with materials. The electrical equipment was not readily accessible in case of service or emergency.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.1200 H01

Serious Gravity 1 1 instance 6 exposed
Issued
Dec 28, 2018
Abate by
Jan 25, 2019
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Plant - On or about 08/30/18 and at times prior thereto employees handled chemicals including (but not limited to) Instapak-50W Components  A and  B (Sealed Air Corporation), liquefied petroleum gas in cylinders, Bates Boothcoating/Glue Release glue (UC Coatings), and Waxilit table lubricant (Weinig). The employer did not train the employees in relation to the Hazard Communication Program and the Right to Know.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1910.95 D01

Other-than-serious 1 instance 4 exposed
Issued
Dec 28, 2018
Abate by
Jan 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure may equal or exceed an 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program.  a) Plant - On or about 08/30/18 and at times prior thereto employees operated machinery including (but not limited to) rip saws, joiners, planers, and routers. The employer did not assess the level of noise in the different areas of the plant in order to determine whether a Hearing Conservation Program was required. (Instantaneous measurement in the area of the router: 85.7 dB).  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 II

Other-than-serious 1 instance 1 exposed
Issued
Dec 28, 2018
Abate by
Jan 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  a) Plant - On or about 08/30/18 and at times prior thereto employees applied lockout/tagout methods during maintenance/repairs of equipment including (but not limited to) rip saws, joiners, planers, and routers. The employer did not certify that the inspections/audits of the specific lockout/tagout procedures had been performed.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C07 IV

Other-than-serious 1 instance 5 exposed
Issued
Dec 28, 2018
Abate by
Jan 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:  a) Plant - On or about 08/30/18 and at times prior thereto employees applied lockout/tagout methods during maintenance/repairs of equipment including (but not limited to) rip saws, joiners, planers, and routers. The employer did not certify that the training had been completed and kept up to date.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Harris Door & Drawer, INC.'s full OSHA safety record →