Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE LINK GROUP INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of THE LINK GROUP INC. in 501 MYRTLE AVE., BROOKLYN, NY 11205 (NAICS 238350). OSHA activity number 343443958.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Link Group INC. — free Get an email when a new federal OSHA severe-injury report for The Link Group INC. is published. One employer, no account, unsubscribe in one click.
Establishment
THE LINK GROUP INC.
Site address
501 MYRTLE AVE.
City
BROOKLYN
State
NY
ZIP
11205
Mailing
6212 5TH AVE., BROOKLYN, NY 11220
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2019
Abate by
Feb 12, 2019
Penalty
Initial $4,168 · Current $4,168
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  a) Ground floor:  Employees used an electric powered chop saw and an electric powered hand drill to build formwork and stair rails. The tools were connected to extension cords, which were routed to outlet devices in the basement and were not provided with a ground fault circuit interrupter. On or about 09/05/18.
Recent events (1)
  • — Z (S) $4168

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2019
Abate by
Feb 12, 2019
Penalty
Initial $4,168 · Current $4,168
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.  a) Ground floor:  Employees used an electric powered chop saw and an electric powered hand drill to build formwork and stair rails. The tools were connected to extension cords, which were routed to outlet devices in the basement and were missing ground pins. On or about 09/05/18.
Recent events (1)
  • — Z (S) $4168

1926.1052 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2019
Abate by
Feb 12, 2019
Penalty
Initial $5,001 · Current $5,001
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.  a) Stairway between ground floor and 2nd floor:  Employees used a stairway to travel between ground floor and 2nd floor. The treads of pan stairs were not filled or fitted with wood or other solid materials at least to the top edge of each pan to prevent tripping hazard. On or about 09/05/18.
Recent events (1)
  • — Z (S) $5001

1926.451 B02

Repeat Gravity 10 1 instance 1 exposed
Issued
Feb 4, 2019
Penalty
Initial $11,669 · Current $11,669
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide:  a) Ground floor, elevator shaft formwork:  An employee used one 2" by 4" wood plank supported by the elevator shaft formwork and a metal pole as a scaffold platform for elevation to build the formwork. The scaffold platform which the employee was on while working was not at least 18 inches wide. On or about 08/07/18.  The Link Group Inc. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.451(b)(2), which was contained in OSHA inspection number 1141454, citation number 1, item number 2 and was affirmed as a final order on 05/25/16, with respect to a workplace located at 312 Fayette Street, Manlius, NY 13104.
Recent events (1)
  • — Z (R) $11669

1904.39 B02

Other-than-serious 1 instance 1 exposed
Issued
Feb 4, 2019
Penalty
Initial $3,789 · Current $3,789
29 CFR 1904.39(b)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation, or the loss of an eye.  a) Jobsite:  The employer did not report within 24-hours a work-related incident which an employee fell from a scaffold platform and was impaled by a metal pole, and was hospitalized for injuries. The incident occurred on 08/07/18, and OSHA was notified about the incident on 09/04/18. On or about 08/07/18.
Recent events (1)
  • — Z (O) $3789

View The Link Group INC.'s full OSHA safety record →