Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SP BUILDERS CONTRACTORS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SP BUILDERS CONTRACTORS INC. in PINTAIL CROSSING 5801 COUNTY ROUTE 41, FARMINGTON, NY 14425 (NAICS 238130). OSHA activity number 343457081.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SP Builders Contractors INC. — free Get an email when a new federal OSHA severe-injury report for SP Builders Contractors INC. is published. One employer, no account, unsubscribe in one click.
Site address
PINTAIL CROSSING 5801 COUNTY ROUTE 41
City
FARMINGTON
State
NY
ZIP
14425
Mailing
431 SAINT MIHIEL DRIVE SUITE 104, RIVERSIDE, NJ 08075
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 1 instance 11 exposed
Issued
Nov 30, 2018
Penalty
Initial $1,663 · Current $1,247 Reduced
29 CFR 1926.404(b)(1)(ii): Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated at 5kW or more, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, were not be protected with ground-fault circuit interrupters.  a)  At the jobsite, on or about 8/16/18:  Workers were using power tools energized with an extension cord without a grounded connection at the source, and where that source was not GFI protected.
Recent events (2)
  • — I (S) $1247.25
  • — Z (S) $1663

1926.404 F01 I

Serious Gravity 1 1 instance 11 exposed
Issued
Nov 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(1)(i): All 3-wire DC premises wiring systems did not have their neutral conductor grounded:  a)  At the jobsite, on or about 8/16/18:  Workers were using power tools energized with an extension cord without a grounded connection at the source, and where that source was not GFI protected.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View SP Builders Contractors INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343457081.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.