Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORFOLK NAVAL SHIPYARD

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORFOLK NAVAL SHIPYARD in NORFOLK NAVAL SHIPYARD BUILDING 369 SAIL LOFT, PORTSMOUTH, VA 23709 (NAICS 336611). OSHA activity number 343486403.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Norfolk Naval Shipyard — free Get an email when a new federal OSHA severe-injury report for Norfolk Naval Shipyard is published. One employer, no account, unsubscribe in one click.
Site address
NORFOLK NAVAL SHIPYARD BUILDING 369 SAIL LOFT
City
PORTSMOUTH
State
VA
ZIP
23709
Mailing
NORFOLK NAVAL SHIPYARD - CODE 106 BUILDING M22, 3RD FLOOR, PORTSMOUTH, VA 23709
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
1000
Ownership type
D

3 citations on file for this inspection.

1910.219 D01

Serious Gravity 5 1 instance 10 exposed
Issued
Dec 17, 2018
Abate by
Jan 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o).  a)    Sail loft: On or about 11/08/2018, the lower pulley of (3) three older model Singer sewing machines were not provided with a guard to protect employees from an ingoing nip point as a result employees were exposed to a possible injury.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 80 exposed
Issued
Dec 17, 2018
Abate by
Jan 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:(a)  a)    Sail loft: On or about 11/08/2018, the vending machines were not used according to its listing and labeling in that the GFCI plug to the vending machines were plugged into an extension cord.     b)    Sail Loft: On or about 11/08/2018, the employer provided a Tappan microwave to be used by employees that was labeled for household use only.      c)    Sail loft: On or about 11/08/2018, a surge strip was not used according to its listing and labeling in that the male attachment plug was plugged into an extension cord.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 2 instances 80 exposed
Issued
Dec 17, 2018
Abate by
Jan 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)    Sail loft: On or about 11/08/2018, the black hurricane fan was not visually inspected before use in that the outer jacket to the flexible cord was pulled away from its housing thereby caused tension on the internal connectors.     b)    Sail loft: On or about 11/08/2018, the vacuum cleaner used by employees to blow air into containments was not visually inspected before use in that the outer jacket to the flexible was damaged and had pulled away from its housing thereby caused tension on the internal connectors.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.