Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAMSUNG AUSTIN SEMICONDUCTOR, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SAMSUNG AUSTIN SEMICONDUCTOR, LLC in 12100 SAMSUNG BOULEVARD, SUITE 100, AUSTIN, TX 78754 (NAICS 334413). OSHA activity number 343488995.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Samsung Austin Semiconductor, LLC — free Get an email when a new federal OSHA severe-injury report for Samsung Austin Semiconductor, LLC is published. One employer, no account, unsubscribe in one click.
Site address
12100 SAMSUNG BOULEVARD, SUITE 100
City
AUSTIN
State
TX
ZIP
78754
Mailing
12100 SAMSUNG BOULEVARD, SUITE 100, AUSTIN, TX 78754
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334413
Employees
3000
Ownership type
A

3 citations on file for this inspection.

1910.29 B13

Serious Gravity 10 7 instances 60 exposed
Issued
Jan 9, 2019
Abate by
Jan 15, 2019
Penalty
Initial $12,934 · Current $7,760 Reduced
29 CFR 1910.29(b)(13): When guardrail systems are used around holes that serve as points of access (such as ladderways), the guardrail system opening did not meet the requirements (b)(13)(i) or (b)(13)(ii) of this section, such as self-closing gates or offset platforms.  On or about 25 September 2018, and at times prior thereto, guardrail systems at the top of vessels did not effectively close the ladderway openings with either gates or offsets, exposing workers to a fall hazard of up to approximately 15 feet to the concrete grade below. a) Sodium Hydroxide (NaOH) Tank, Vessel U2101, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 13 feet to the concrete grade. b) Sulfuric Acid Tank, Vessel U2103, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 15 feet to the concrete grade. c) Sulfuric Acid Tank, Vessel U2102, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 15 feet to the concrete grade. d) Phosphoric Acid Tank, Vessel U2107, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 13 feet to the concrete grade. e) Argon Fluoride (ArF) Thinner Collection Tank, Vessel U2106, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 13 feet to the concrete grade. f) Sulfuric Acid Tank A did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 13 feet to the concrete grade. g) CuWW Dilute Copper Waste Tank, Vessel U35B, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 12 feet to the concrete grade.
Recent events (2)
  • — I (S) $7760.4
  • — Z (S) $12934

1910.119 L01

Serious Gravity 1 1 instance 7 exposed
Issued
Jan 9, 2019
Abate by
Jan 15, 2019
Penalty
Initial $6,097 · Current $3,658 Reduced
29 CFR 1910.119(l)(1): The employer did not implement procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process.  On or about 25 September 2018, and at times prior thereto, the employer did not implement management of change procedures for a change in process chemicals within the Fab 2 Base Room.
Recent events (2)
  • — I (S) $3658.2
  • — Z (S) $6097

1910.147 C02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 9, 2019
Abate by
Jan 15, 2019
Penalty
Initial $6,097 · Current $3,658 Reduced
29 CFR 1910.147(c)(2)(ii): An energy isolating device that was capable of being locked out, did not utilize a lockout device, which rendered the machine or equipment inoperative.  On or about 25 September 2018, and at times prior thereto, repair work on the main exhaust lines running through the sub fabs did not include lock-out of the lines and the equipment upstream and downstream, exposing the workers to the hazards of Hydrogen Fluoride (HF) gas.
Recent events (2)
  • — I (S) $3658.2
  • — Z (S) $6097

View Samsung Austin Semiconductor, LLC's full OSHA safety record →