AUSTIN, TX —
OSHA Inspection: SAMSUNG AUSTIN SEMICONDUCTOR, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SAMSUNG AUSTIN SEMICONDUCTOR, LLC in 12100 SAMSUNG BOULEVARD, SUITE 100, AUSTIN, TX 78754 (NAICS 334413). OSHA activity number 343488995.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMSUNG AUSTIN SEMICONDUCTOR, LLC
- Site address
- 12100 SAMSUNG BOULEVARD, SUITE 100
- City
- AUSTIN
- State
- TX
- ZIP
- 78754
- Mailing
- 12100 SAMSUNG BOULEVARD, SUITE 100, AUSTIN, TX 78754
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334413
- Employees
- 3000
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.29 B13
- Issued
- Jan 9, 2019
- Abate by
- Jan 15, 2019
- Penalty
- Initial $12,934 · Current $7,760 Reduced
General-duty citation text
29 CFR 1910.29(b)(13): When guardrail systems are used around holes that serve as points of access (such as ladderways), the guardrail system opening did not meet the requirements (b)(13)(i) or (b)(13)(ii) of this section, such as self-closing gates or offset platforms. On or about 25 September 2018, and at times prior thereto, guardrail systems at the top of vessels did not effectively close the ladderway openings with either gates or offsets, exposing workers to a fall hazard of up to approximately 15 feet to the concrete grade below. a) Sodium Hydroxide (NaOH) Tank, Vessel U2101, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 13 feet to the concrete grade. b) Sulfuric Acid Tank, Vessel U2103, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 15 feet to the concrete grade. c) Sulfuric Acid Tank, Vessel U2102, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 15 feet to the concrete grade. d) Phosphoric Acid Tank, Vessel U2107, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 13 feet to the concrete grade. e) Argon Fluoride (ArF) Thinner Collection Tank, Vessel U2106, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 13 feet to the concrete grade. f) Sulfuric Acid Tank A did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 13 feet to the concrete grade. g) CuWW Dilute Copper Waste Tank, Vessel U35B, did not have a gate or offset at the ladderway opening, exposing personnel to a fall of approximately 12 feet to the concrete grade.
Recent events (2)
- — I (S) $7760.4
- — Z (S) $12934
1910.119 L01
- Issued
- Jan 9, 2019
- Abate by
- Jan 15, 2019
- Penalty
- Initial $6,097 · Current $3,658 Reduced
General-duty citation text
29 CFR 1910.119(l)(1): The employer did not implement procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process. On or about 25 September 2018, and at times prior thereto, the employer did not implement management of change procedures for a change in process chemicals within the Fab 2 Base Room.
Recent events (2)
- — I (S) $3658.2
- — Z (S) $6097
1910.147 C02 II
- Issued
- Jan 9, 2019
- Abate by
- Jan 15, 2019
- Penalty
- Initial $6,097 · Current $3,658 Reduced
General-duty citation text
29 CFR 1910.147(c)(2)(ii): An energy isolating device that was capable of being locked out, did not utilize a lockout device, which rendered the machine or equipment inoperative. On or about 25 September 2018, and at times prior thereto, repair work on the main exhaust lines running through the sub fabs did not include lock-out of the lines and the equipment upstream and downstream, exposing the workers to the hazards of Hydrogen Fluoride (HF) gas.
Recent events (2)
- — I (S) $3658.2
- — Z (S) $6097
More inspections at Samsung Austin Semiconductor, LLC
View Samsung Austin Semiconductor, LLC's full OSHA safety record →
More inspections in this industry (NAICS 334413)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343488995.