OSHA Inspection: ECO SERVICES OPERATIONS CORP.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of ECO SERVICES OPERATIONS CORP. in 8615 MANCHESTER ST, HOUSTON, TX 77012 (NAICS 325199). OSHA activity number 343490306.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ECO Services Operations Corp. — free Get an email when a new federal OSHA severe-injury report for ECO Services Operations Corp. is published. One employer, no account, unsubscribe in one click.
Site address
8615 MANCHESTER ST
City
HOUSTON
State
TX
ZIP
77012
Mailing
8615 MANCHESTER ST, HOUSTON, TX 77012
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325199
Employees
126
Ownership type
A

2 citations on file for this inspection.

1910.132 A

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 18, 2018
Abate by
Feb 6, 2019
Penalty
Initial $12,934 · Current $9,700 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    (a) Eco Services facility: On September 21,2018, the employer did not ensure that protective equipment was used when an employee operated valves on track 5 spot 7 which contained spent sulfuric acid. This condition exposed employees to chemical burns.
Recent events (2)
  • — I (S) $9700
  • — Z (S) $12934

1910.147 D03

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 18, 2018
Abate by
Feb 6, 2019
Penalty
Initial $12,934 · Current $9,701 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    (a) Eco Services facility: On September 21,2018, the employer did not ensure that all energy isolating devices that were needed to control the energy on track 5 spot 7 were physically located and operated in such a manner as to isolate the equipment from the energy source. This condition exposed employees to chemical burns.