Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NISSHINBO AUTOMOTIVE MANUFACTURING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NISSHINBO AUTOMOTIVE MANUFACTURING, INC. in 14187 NISSHINBO DRIVE, COVINGTON, GA 30014 (NAICS 336390). OSHA activity number 343490793.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nisshinbo Automotive Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Nisshinbo Automotive Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
14187 NISSHINBO DRIVE
City
COVINGTON
State
GA
ZIP
30014
Mailing
14187 NISSHINBO DRIVE, COVINGTON, GA 30014
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336390
Employees
300
Ownership type
A

8 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 4, 2019
Abate by
Jan 31, 2019
Penalty
Initial $7,391 · Current $7,500
29 CFR 1910.28(b)(1)(i): Each employee on a walking/working surface having an unprotected side or edge which was four feet (1.2m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    On 9/27/18, in the wastewater building, at the wastewater platform an 8.6 in. section of guardrails (upper and lower) were missing exposing employees to falls greater than 4 ft..
Recent events (2)
  • — I (S) $7500
  • — Z (S) $7391

1910.28 B03 I A

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 4, 2019
Abate by
Jan 31, 2019
Penalty
Initial $5,543 · Current $0 Reduced
29 CFR 1910.28(b)(3)(i)(A): The employer did not ensure that each employee on a walking-working surface was protected from falling into any hole or pit that was 4 feet (1.2 m) or more above a lower level by a cover or covers.    On 9/26/18, at the wastewater platform, the employer did not ensure holes measuring 10 in. x 20 in. were covered.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5543

1910.37 A03

Other-than-serious 1 instance 1 exposed
Issued
Jan 4, 2019
Penalty
Initial $5,543 · Current $3,000 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed.    On or about 9/26/18, egress routes at operators work areas were blocked by product stored at the area. Egress routes ranged from 16 in. to 22 in..
Recent events (2)
  • — I (O) $3000
  • — Z (S) $5543

1910.147 C06 I

Serious Gravity 10 1 instance 10 exposed
Issued
Jan 4, 2019
Abate by
Feb 22, 2019
Penalty
Initial $12,934 · Current $9,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.    On 9/26/18, at the Covington facility, the employer did not conduct a periodic inspection of the Lockout program on an at least annual basis. Deficiencies in the procedures included not including all energies or the magnitudes of those energies and did not include all Authorized employees.
Recent events (2)
  • — I (S) $9000
  • — Z (S) $12934

1910.212 A01

Serious Gravity 10 7 instances 10 exposed
Issued
Jan 4, 2019
Abate by
Jan 31, 2019
Penalty
Initial $12,934 · Current $9,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    On 9/26/18, at the Covington facility, employees were exposed to fingertip and hand injuries as various machines and lines were not guarded. Instances included:    a - CL07 conveyor @ Unload conveyor - in running nip points where belt runs across geared roller  b - Chevaler Milling machine - in Maintenance shop - no chuck guard  c - Clausing 20 Drill Press - in Maintenance Shop - no chuck guard  d - Delta Drill Press 12" machine - in Maintenance Shop - no chuck guard  e - Band Saw (no manufacturing information) - in Maintenance Shop - Unused portion of blade left unguarded (6 1/2")    f - Cure Press Doors - pneumatic door operates at approximately 72 psi   g - Drayton mixers - Wastewater Building
Recent events (2)
  • — I (S) $9000
  • — Z (S) $12934

1910.219 F03

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 4, 2019
Abate by
Jan 31, 2019
Penalty
Initial $9,239 · Current $6,000 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed.    On 9/27/18, at the Covington facility in the wastewater building, the employer did not ensure chains and sprockets were enclosed on the wastewater equipment.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $9239

1910.242 B

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 4, 2019
Abate by
Jan 31, 2019
Penalty
Initial $7,391 · Current $5,000 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i..    On 9/26/18, at the Covington facility, employees were exposed to embolism hazards as air guns used for cleaning would not reduce to less than 30 psi when dead ended. Compressed air measured 70 psi.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7391

1910.305 G01 IV A

Deleted Other-than-serious 1 instance 4 exposed
Issued
Jan 4, 2019
Abate by
Jan 31, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  On 9/26/18, at the Covington facility in the maintenance shop, the employer permitted retractable electrical extension cords to be used in lieu of permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Nisshinbo Automotive Manufacturing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343490793.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.