Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: S P E INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of S P E INC in 605 WASHINGTON STREET, MANITOWOC, WI 54220 (NAICS 238120). OSHA activity number 343495297.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S P E INC — free Get an email when a new federal OSHA severe-injury report for S P E INC is published. One employer, no account, unsubscribe in one click.
Establishment
S P E INC
Site address
605 WASHINGTON STREET
City
MANITOWOC
State
WI
ZIP
54220
Mailing
1645 E ELM DRIVE, LITTLE CHUTE, WI 54140
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
40
Ownership type
A

6 citations on file for this inspection.

1926.20 B02

Other-than-serious 1 instance 1 exposed
Issued
Nov 28, 2018
Abate by
Jan 4, 2019
Penalty
Initial $9,054 · Current $12,934
29 CFR 1926.20(b)(2):  It shall be the responsibility of the employer to initiate and maintain programs as may be necessary to comply with accident prevention; such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.    On or about September 26, 2018 at 605 Washington Street in Manitowoc, the employer did not conduct adequate safety inspections prior to employees working on a steel beam structure at greater than forty feet above surface level.  Employee climbing boom lift basket guardrails, fall arrest system installed with a greater than six feet free fall and used with two snap-hooks connected to body harness D-ring, body harness D-ring positioned below shoulder blades, and two tie-off adapter ends connected to the lanyard snap-hook.
Recent events (2)
  • — I (O) $12934
  • — Z (S) $9054

1926.453 B02 IV

Other-than-serious 1 instance 1 exposed
Issued
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.453(b)(2)(iv): Employees shall always stand firmly on the floor of the basket, and shall not sit or climb on the edge of the basket or use planks, ladders, or other devices for a work position.    On September 26, 2018 at 605 Washington Street in Manitowoc, an employee was climbing out/in of an aerial lift basket to access/egress the top of a steel beam at greater than forty feet above surface level.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 D06 III

Other-than-serious 1 instance 1 exposed
Issued
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(6)(iii):  Unless the snap-hook is a locking type and designed for the following connections, snap-hooks shall not be engaged to a D-ring to which another snap-hook or other connector is attached; reference CFR 1926.760(d)(1) Steel Erection Subpart R.    On September 26, 2018 at 605 Washington Street in Manitowoc, an employee was accessing/egressing a structure and climbing and working at the top of a vertical beam at greater than forty feet above surface level using a personal fall arrest system with two snap-hooks connected to the body harness D-ring; a double legged lanyard snap-hook and a D-ring extension snap-hook.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 D06 V

Other-than-serious 2 instances 1 exposed
Issued
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(6)(v):  Unless the snap-hook is a locking type and designed for the following connections, snap-hooks shall not be engaged to any object which is incompatibly shaped or dimensioned in relation to the snap-hook such that unintentional disengagement could occur by the connected object being able to depress the snap-hook keeper and release itself.    a)  On September 26, 2018 at 605 Washington Street in Manitowoc, an employee who was working on a vertical beam greater than forty feet above surface level had anchored his personal fall arrest system with the lanyard snap-hook connected to two loop ends of a cable tie-off adapter which was basket wrapped around a chevron beam.    b)  On or about September 26, 2018 at 605 Washington Street in Manitowoc, an employee who was accessing a steel structure greater than forty feet above surface level had anchored his personal fall arrest system with the lanyard snap-hook connected to two ring ends of a wire rope tie-off adapter which was basket wrapped around the walking surface beam.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 D16 III

Other-than-serious 2 instances 1 exposed
Issued
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest system when stopping a fall shall be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level; reference CFR 1926.760(d)(1) Steel Erection.    a)  On September 26, 2018 at 605 Washington Street in Manitowoc, an employee was accessing a horizontal beam from a boom lift basket at greater than forty feet above surface level using a personal fall arrest system installed with a greater than six feet free fall.  Eight feet long wire rope tie-off adapter basket wrapped on access point beam and connected to stretchable lanyard.    b)  On September 26, 2018 at 605 Washington Street in Manitowoc, an employee was working at the top of a vertical beam at greater than forty feet above surface level using a personal fall arrest system installed with a greater than six feet free fall.  Four feet long, orange colored, loop end cable tie-off adapter basket wrapped on a chevron beam and connected to a stretchable lanyard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 D17

Other-than-serious 1 instance 1 exposed
Issued
Nov 28, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head.    On September 26, 2018 at 605 Washington Street in Manitowoc, an employee was working on a steel structure at greater than forty feet above surface level using a personal fall arrest system with the body harness D-ring positioned below the shoulder blades.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View S P E INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343495297.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.