Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ENGINEERED FLOORS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ENGINEERED FLOORS, LLC in 3201 N. BYPASS, DALTON, GA 30720 (NAICS 313110). OSHA activity number 343495685.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Engineered Floors, LLC — free Get an email when a new federal OSHA severe-injury report for Engineered Floors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3201 N. BYPASS
City
DALTON
State
GA
ZIP
30720
Mailing
1502 CORONET DR., DALTON, GA 30721
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313110
Employees
160
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Mar 26, 2019
Penalty
Initial $13,260 · Current $7,956 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy:    (A)  A specific statement of the intended use of the procedure;  (B)  Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;  (C)  Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and  (D)  Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.     a) Signal Machine Production Area- Conveyor Belt and Rollers: On or before September 21, 2018, and at times prior, the employer exposed employees to electrical, struck-by and caught-in hazards, in that the employer did not have a specific procedure to lockout the Signal Machine (S/N 60725), also called the Tile Splitter Machine, when performing duties associated with troubleshooting and cleaning on the machine.    b) Signal Machine Production Area-Electrical Panel Door: On or before September 26, 2018, and at times prior, the employer exposed employees to electrical, struck-by and caught-in hazards, in that the employer did not have a specific procedure to lockout the Signal Machine (S/N 60725), also called the Tile Splitter Machine, when performing duties associated with troubleshooting and cleaning on the machine.
Recent events (2)
  • — I (S) $7956
  • — Z (S) $13260

1910.147 C07 I

Serious Gravity 10 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Mar 26, 2019
Penalty
Initial $13,260 · Current $7,956 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    a) Signal Machine Production Area - Conveyor Belt and Rollers: On or before September 19, 2018, and at times prior, the employer exposed employees to struck-by, and caught-in hazards, in that the employer did not provide affected and authorized employees training to lockout the Signal Machine (S/N 60725) during troubleshooting and cleaning.    b) Signal Machine Production Area - Electrical Panel Door: On or before September 19, 2018, and at times prior, the employer exposed employees to electrical, struck-by, and caught-in hazards, in that the employer did not provide affected and authorized employees training to lockout the Signal Machine (S/N 60725) during troubleshooting and cleaning.
Recent events (2)
  • — I (S) $7956
  • — Z (S) $13260

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 14, 2019
Abate by
Apr 2, 2019
Penalty
Initial $13,260 · Current $7,956 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    a) Signal Machine Production Area -Conveyor Belt, Figure 8 Configuration: On or before September 21, 2018, and at times prior, the employer exposed employees to struck-by and caught-in hazards, in that the employer did not have a guard at the point of operation on the Signal Machine's (S/N 60725) Figure 8 Belt when employees were required to cut scrap material and/or strings off of the carpet.
Recent events (2)
  • — I (S) $7956
  • — Z (S) $13260

1910.132 D02

Other-than-serious 1 instance 8 exposed
Issued
Mar 14, 2019
Abate by
Mar 26, 2019
Penalty
Initial $1,063 · Current $638 Reduced
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:      a) Warehouse and Production Areas: On or before September 21, 2018, and at times prior, the employer exposed employees to electrical, struck-by and caught-in hazards associated with carpet mill activities in that the employer did not certify that a workplace hazard assessment had been completed.
Recent events (2)
  • — I (O) $637.8
  • — Z (O) $1063

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Mar 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   a)  Signal Machine Production Area- Sew-on Area: On or about September 21, 2018, and at times prior, the employer exposed employees to electrical shock hazards in that an extension cord was used with an industrial fan (Heat Buster; model number: unknown, S/N: B00) as a permanent source for wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 1 exposed
Issued
Mar 14, 2019
Abate by
Mar 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  a) Warehouse and Glue Table: On or before September 21, 2018, and at times prior, the employer exposed employees to chemical hazards associated with carpet mill activities in that the employer did not have a list of chemicals on site such as, but not limited to, glue for the backs of carpet and propane for forklifts.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 1 exposed
Issued
Mar 14, 2019
Abate by
Mar 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.   a) Warehouse and Glue Table: On or before September 21, 2018, and at times prior, the employer exposed employees to chemical hazards associated with carpet mill activities in that the employer did not have Material Safety Data Sheets for chemicals that are used on site such as, but not limited to, glue for the backs of carpet and propane for forklifts.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Engineered Floors, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343495685.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.