Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SHOTO CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SHOTO CORPORATION in 4747 WOODLAND DRIVE, TWO RIVERS, WI 54241 (NAICS 337211). OSHA activity number 343536041.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Shoto Corporation — free Get an email when a new federal OSHA severe-injury report for Shoto Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
SHOTO CORPORATION
Site address
4747 WOODLAND DRIVE
City
TWO RIVERS
State
WI
ZIP
54241
Mailing
4747 WOODLAND DRIVE, TWO RIVERS, WI 54241
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337211
Employees
30
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 30 exposed
Issued
Feb 4, 2019
Abate by
Apr 30, 2019
Penalty
Initial $5,636 · Current $2,818 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees working at or near dry dust collection systems (indoor enclosureless bag separator and upstream ducting) handling combustible wood dust were exposed to wood dust fire hazards during the operation and maintenance of the dust collection system:    a)  An indoor enclosureless bag separator (Dustek M1500 Dust Collection System) with positive pressure air-material inlet and four unenclosed dust filter bags was used to collected combustible wood dust fines from a Shoda High Speed NC Router and two Crouch Pedestal Drum sanders. Employees were exposed to the hazards of fire and flash fire from working in close proximity to the indoor enclosureless dust collector and upstream ducting and manually emptying the bags of collected combustible wood dust in the event of the presence of an internal fire, ember or spark.    b)  An indoor enclosureless bag separator (Dustek C1500 Dust Collection System) with positive pressure air-material inlet and four unenclosed dust filter bags was used to collected combustible wood dust fines from a Timesavers Wide Belt Sander, a Shoda High Speed NCW Router, a Biesse Rover CNC and a Powermatic saw. Employees were exposed to the hazards of fire and flash fire from working in close proximity to the indoor enclosureless dust collector and upstream ducting and manually emptying the bags of collected combustible wood dust in the event of the presence of an internal fire, ember or spark.    c)  Three indoor enclosureless bag separators (Dustek Dust Collection Systems) with positive pressure air-material inlet and four unenclosed dust filter bags was used to collected combustible wood dust fines from different types of wood working equipment. Employees were exposed to the hazards of fire and flash fire from working in close proximity to the indoor enclosureless dust collector and upstream ducting and manually emptying the bags of collected combustible wood dust in the event of the presence of an internal fire, ember or spark.
Recent events (2)
  • — I (S) $2818
  • — Z (S) $5636

1910.107 C06

Serious Gravity 5 1 instance 6 exposed
Issued
Feb 4, 2019
Abate by
May 31, 2019
Penalty
Initial $4,508 · Current $2,254 Reduced
29 CFR 1910.107(c)(6):  Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations:    Electrical wiring and equipment located in the spray area where red adhesive F-150 and F-151 (flammable - category 2) was being sprayed were not of explosion-proof type approved for Class I, group D locations and did not conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical equipment such as, but not limited to: 1) electrical outlets, breaker panels and a heater control were located within 20 feet (horizontally) of the spray area; and 2) electrical pendant outlets with retractable extension cords were located within 10 feet (vertically) of the spray area.
Recent events (2)
  • — I (S) $2254
  • — Z (S) $4508

View Shoto Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343536041.