Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: METRIC CONSTRUCTION CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of METRIC CONSTRUCTION CORPORATION in 200 ESTEN AVE., PAWTUCKET, RI 02860 (NAICS 236220). OSHA activity number 343552857.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Metric Construction Corporation — free Get an email when a new federal OSHA severe-injury report for Metric Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
200 ESTEN AVE.
City
PAWTUCKET
State
RI
ZIP
02860
Mailing
55 HENSHAW STREET, BRIGHTON, MA 02135
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
36
Ownership type
A

13 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 3 instances 11 exposed
Issued
Apr 15, 2019
Abate by
May 1, 2019
Penalty
Initial $9,282 · Current $6,500 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person:    (a) Throughout the building:  On or about 11/1/2018, 11/27/2018, and 11/30/2018,  the employer did not initiate and maintain a program that provided frequent and regular inspections of the jobsite by a competent person, exposing workers to numerous health and safety hazards.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9282

1926.25 A

Deleted Serious Gravity 10 3 instances 11 exposed
Issued
Apr 15, 2019
Abate by
Apr 22, 2019
Penalty
Initial $9,282 · Current $0 Reduced
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:  (a) Throughout the building:  On or about 11/1/2018, 11/27/2018, and 11/30/2018, construction debris was not kept cleared from the work areas and passageways in the building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9282

1926.150 A01

Serious Gravity 10 1 instance 12 exposed
Issued
Apr 15, 2019
Abate by
Apr 22, 2019
Penalty
Initial $9,282 · Current $6,500 Reduced
29 CFR 1926.150(a)(1): The employer did not develop and maintain a fire protection program to be followed throughout all phases of construction and demolition work, and/or did not provide for the firefighting equipment as specified in this subpart:    (a) On the 3rd floor:  On or about 11/1/2018, the employer did not have an effective fire protection plan, in that sparks from operations on the 5th floor were allowed to fall onto debris on the 3rd floor, causing the debris to smolder.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9282

1926.150 A02

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.150(a)(2): Access to all available firefighting equipment was not maintained at all times:  (a) On the 3rd floor:  On or about 10/23/2018, the only serviceable portable fire extinguisher in the area was blocked by a sheet of plywood.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.150 A04

Serious Gravity 10 7 instances 8 exposed
Issued
Apr 15, 2019
Abate by
Apr 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.150(a)(4): All firefighting equipment was not periodically inspected and maintained in operating condition. Defective equipment was not immediate replaced:  (a) Throughout the 5-story building:  On or about 10/23/208, numerous unserviceable and expended fire extinguishers were found throughout the building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 I02 I

Other-than-serious 2 instances 20 exposed
Issued
Apr 15, 2019
Abate by
Apr 19, 2019
Penalty
Initial $9,282 · Current $6,500 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:    (a) On the first floor:  On or about 10/23/2018, the fuse panel had an unguarded slot where a circuit breaker had been removed, exposing live electrical parts.    (b) On the 3rd floor:  On or about 10/23/2018, a bulb was missing from the socket on a string of temporary lighting, hanging approximately chest high, exposing live electrical parts.
Recent events (2)
  • — I (O) $6500
  • — Z (S) $9282

1926.405 A02 II E

Other-than-serious 1 instance 2 exposed
Issued
Apr 15, 2019
Abate by
Apr 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    (a) On the 1st, 3rd and 4th floor:  On or about 10/23/2018, lamps used for temporary lighting, with broken and missing bulbs, were hanging less than 4 feet above the ground and were not protected from contact or breakage.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.501 A02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Apr 15, 2019
Abate by
Apr 19, 2019
Penalty
Initial $9,282 · Current $0 Reduced
29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work on, had the strength and structure integrity to support employees safely:  (a) At the northwest corner of the 3rd floor:  On or about 10/22/2018, the employer did not determine that the walking/working surface on which the workers were working had the strength and structural integrity to support them safely, in that the floor was loaded with scrap concrete and construction debris, causing it to collapse down to the 1st floor of the building.
Recent events (3)
  • — D (S) $0
  • — C (S) $9282
  • — Z (S) $9282

1926.857 A

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Apr 15, 2019
Abate by
Apr 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.857(a): Storage of waste material and debris on the floor exceeded the allowable floor loads:  (a) In the northwest corner of the 3rd floor:  On or about 10/22/2018, , pre-positioned metal, wood and concrete debris exceeded the allowable floor loads, causing the 3rd floor to collapse to the 1st floor.
Recent events (3)
  • — D (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B04 I

Serious Gravity 10 1 instance 9 exposed
Issued
Apr 15, 2019
Abate by
Apr 19, 2019
Penalty
Initial $9,282 · Current $6,500 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:    (a) Throughout the building:  On or about 11/1/2018, employees on walking/working surfaces were exposed to unprotected holes in the floor, which were approximately 12-15 feet above the next lower level.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9282

1926.502 I04

Serious Gravity 10 1 instance 30 exposed
Issued
Apr 15, 2019
Abate by
Apr 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:  (a) Throughout the building:  On or about 10/23/2018, floor holes that were covered were not marked "Hole" or "Cover" to warn of the hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 15, 2019
Penalty
Initial $9,282 · Current $6,500 Reduced
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:    (a) On the north end of the 5th floor:  On or about 11/1/2018, the fall arrest system connector was not drop forged, in that a rope was tied to the anchorage point of the roofing bracket.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9282

1926.502 D15

Serious Gravity 10 3 instances 6 exposed
Issued
Apr 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and/or were not capable of supporting at least 5,000 pounds per employee:  (a) On the 5th floor:  On or about 11/1/2018, employees misused roofing brackets attached to round columns, which was not what they were designed or intended to be used for.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Metric Construction Corporation's full OSHA safety record →