HARAHAN, LA ·
OSHA Inspection: RUELCO, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RUELCO, INC. in 1209 DISTRIBUTORS ROW, HARAHAN, LA 70123 (NAICS 332912). OSHA activity number 343554366.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUELCO, INC.
- Site address
- 1209 DISTRIBUTORS ROW
- City
- HARAHAN
- State
- LA
- ZIP
- 70123
- Mailing
- 1209 DISTRIBUTORS ROW, HARAHAN, LA 70123
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332912
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Dec 28, 2018
- Penalty
- Initial $5,174 · Current $3,104 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about October 24, 2018, in the Mill and manual departments, the employer did not develop specific lockout/tagout procedures for the following equipment during servicing and maintenance: a) Ace Robot (Serial #M-710IC50) b) Victor High Speed Lathe c) ACRA Manual Mill
Recent events (2)
- · I (S) $3104.4
- · Z (S) $5174
1910.147 C06 I
- Issued
- Dec 28, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about October 24, 2018, in the Mill and manual departments, the employer failed to conduct a periodic inspection of the energy control procedure at least annually: a) Ace Robot (Serial #M-710IC50) b) Victor High Speed Lathe c) ACRA Manual Mill
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Dec 28, 2018
- Penalty
- Initial $5,174 · Current $3,104 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts and flying chips: On or about October 24, 2018, in Manual department, the employer failed to guard the chucks on the Victor High Speed Lathe and the ACRA Manual Mill.
Recent events (2)
- · I (S) $3104.4
- · Z (S) $5174
More inspections in this industry (NAICS 332912)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343554366.