Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: SUNRISE ERECTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUNRISE ERECTORS, INC. in 290 PINE STREET, CANTON, MA 02021 (NAICS 238120). OSHA activity number 343555793.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunrise Erectors, INC. for free Get an email when a new federal OSHA severe-injury report for Sunrise Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
290 PINE STREET
City
CANTON
State
MA
ZIP
02021
Mailing
290 PINE STREET, CANTON, MA 02021
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
350
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C01

Other-than-serious 1 instance 40 exposed
Issued
Dec 19, 2018
Abate by
Feb 11, 2019
Penalty
Initial $7,391 · Current $5,174 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    Location:  Fabrication Area    When employees were servicing or maintaining electrical equipment used to fabricate exterior wall systems, the employer did not establish an energy control program to protect the employees from injuries related to the unexpected energizing, start-up, or release of stored energy.    Such equipment included:    Rollers, shapers, shears, brakes, and CNC machines
Recent events (2)
  • · I (O) $5173.7
  • · Z (S) $7391

1910.212 A03 II

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 19, 2018
Abate by
Feb 11, 2019
Penalty
Initial $11,086 · Current $7,760 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed so as to prevent the operator from having any part of their body in the danger zone during the operating cycle:    Location: Fabrication Shop      Employees were exposed to laceration and crush hazards while operating the Primeline shear where the guard for the blade and the hold downs was inadequate in that it contained a 40 inch long hinged section that could be opened during operation.
Recent events (2)
  • · I (S) $7760.2
  • · Z (S) $11086

1904.39 A02

Other-than-serious 1 instance 350 exposed
Issued
Dec 19, 2018
Abate by
Dec 28, 2018
Penalty
Initial $9,239 · Current $1,000 Reduced
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye.      The employer did not report, within 24 hours, a work-related finger amputation that occurred in the fabrication shop on September 26th, 2018.
Recent events (2)
  • · I (O) $1000
  • · Z (O) $9239

View Sunrise Erectors, INC.'s full OSHA safety record →