TAMPA, FL —
OSHA Inspection: THEOCHEM LABORATORIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of THEOCHEM LABORATORIES, INC. in 7373 ROWLETT PARK DRIVE, TAMPA, FL 33610 (NAICS 325611). OSHA activity number 343561015.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THEOCHEM LABORATORIES, INC.
- Site address
- 7373 ROWLETT PARK DRIVE
- City
- TAMPA
- State
- FL
- ZIP
- 33610
- Mailing
- 7373 ROWLETT PARK DRIVE, TAMPA, FL 33610
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325611
- Employees
- 35
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.22 A03
- Issued
- Feb 13, 2019
- Abate by
- Mar 12, 2019
- Penalty
- Initial $4,508 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(3): Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice: a) On or about October 26, 2018, at the acid room, a floor hole measuring 28 inches long with an exposed upright pipe about 7 inches up was obstructing the forklift travel path, exposing employees to falls and struck-by hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $4508
1910.151 C
- Issued
- Feb 13, 2019
- Abate by
- Mar 12, 2019
- Penalty
- Initial $4,508 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about 10/26/2018, at the facility, eyewash/shower stations in areas where corrosives were handled were not kept in a suitable condition, exposing employees to eye and/or face injuries: a) In the acid room, on the floor level, an eyewash station was obstructed with large parts inside its basin. b) In the acid room, on the upper level, an eyewash station had a very weak flow rate that was not able to flush an employee's eyes with the right volume of water. c) In the acid room, on the upper level, a shower station was not equipped with a pull down lever to activate it, but a turn valve located in the rear and not easily accessible in event of exposure.
Recent events (2)
- — I (S) $3000
- — Z (S) $4508
More inspections at Theochem Laboratories, INC.
View Theochem Laboratories, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325611)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343561015.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.