ATLANTA, GA —
OSHA Inspection: THEOCHEM LABORATORIES, INC.
Monitoring inspection · Safety discipline
At a glance
On , OSHA opened a monitoring safety inspection of THEOCHEM LABORATORIES, INC. in 3780 BROWN MILLS RD., ATLANTA, GA 30354 (NAICS 325611). OSHA activity number 343579397.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THEOCHEM LABORATORIES, INC.
- Site address
- 3780 BROWN MILLS RD.
- City
- ATLANTA
- State
- GA
- ZIP
- 30354
- Mailing
- 3780 BROWNS MILL RD. SE, ATLANTA, GA 30354
What kind of inspection was it?
- Inspection type
- Monitoring (D)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325611
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A03
- Issued
- Apr 25, 2019
- Abate by
- Jun 30, 2019
- Penalty
- Initial $7,293 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(3): Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. a) Crystal Room: On or before November 1, 2018, and at times prior, the employer exposed employees to slips and falls caused by wet floors. The crystal room area had very slick floors due to water from numerous leaks in the ceiling. b) Warehouse Area: On or before November 1, 2018, and at times prior, the employer exposed employees to slips and falls caused by wet and soapy floors. The warehouse areas had slick floors from water due to numerous leaks in the ceiling.
Recent events (2)
- — I (S) $3000
- — Z (S) $7293
1910.147 C04 II
- Issued
- Apr 25, 2019
- Abate by
- Jun 30, 2019
- Penalty
- Initial $5,834 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy. a) Production Area: On or before November 1, 2018, and at times prior, the employer exposed employees to electrical and struck-by hazards in that the LOTO procedures being utilized were not detailed when locking out equipment such as, but not limited to, blower and mixer.
Recent events (2)
- — I (S) $2000
- — Z (S) $5834
1910.147 C07 I
- Issued
- Apr 25, 2019
- Abate by
- May 21, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) Crystal Room: On or before November 1, 2018, and at times prior, the employer exposed employees to electrical and struck-by hazards in that the employee did not have adequate training to ensure that they had the knowledge and skills needed to LOTO equipment such as, but not limited to, blower, mixer, etc. b) Rework Area: On or before November 1, 2018, and at times prior, the employer exposed employees to electrical and struck-by hazards in that the employee did not have adequate training to ensure that they had the knowledge and skills needed to LOTO equipment such as, but not limited to, electrical panel leading to lights in crystal room, box machine, pail line.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Apr 25, 2019
- Abate by
- May 21, 2019
- Penalty
- Initial $4,376 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Rework Area - Electrical Panel: On or before November 1, 2018, and at times prior, the employer exposed employees to shock hazards, in that the employer did not ensure that the electrical panel was not blocked as required. Pallets and super sacks of rework soap were haphazardly placed approximately 15.75" in front of the electrical panel.
Recent events (2)
- — I (S) $2000
- — Z (S) $4376
1910.1200 H
- Issued
- Apr 25, 2019
- Abate by
- May 21, 2019
- Penalty
- Initial $5,834 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) on hazardous chemicals in their work area: a) Production Areas: On or before November 1, 2018, and at times prior, the employer exposed employees to chemical hazards by not providing training on the chemicals used in the manufacture of soap products such as, but not limited to, Sodium Hydroxide, White Wonder Suds, Crystal Drain Opener, Pink Hi-Active Beads, etc.
Recent events (2)
- — I (S) $3000
- — Z (S) $5834
1910.132 D02
- Issued
- Apr 25, 2019
- Abate by
- Jul 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not identify a document as a certification of hazard assessment: a) Production: On or before November 1, 2018, and at times prior, the employer exposed employees to chemical, slip and shock hazards by not certifying a PPE assessment of the areas used to manufacture and/or package soap products. b) Warehouse: On or before November 1, 2018, and at times prior, the employer exposed employees to chemical, slip and shock hazards by not certifying a PPE assessment of the areas used for storage of soap products and/or feed material.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Theochem Laboratories, INC.
View Theochem Laboratories, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325611)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343579397.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.