Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: OWAN, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of OWAN, LLC in 6745 W SUNDUST ROAD, CHANDLER, AZ 85226 (NAICS 441229). OSHA activity number 343561544.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Owan, LLC for free Get an email when a new federal OSHA severe-injury report for Owan, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
OWAN, LLC
Site address
6745 W SUNDUST ROAD
City
CHANDLER
State
AZ
ZIP
85226
Mailing
6745 W SUNDUST ROAD, CHANDLER, AZ 85226
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441229
Employees
10
Ownership type
Private (A)

8 citations on file for this inspection.

1910.106 E02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 28, 2018
Abate by
Dec 17, 2018
Penalty
Initial $3,326 · Current $1,670 Reduced
29 CFR 1910.106(d)(5)(iii): 29 CFR 1910.106(d)(5)(iii) Flammable storage was not kept in closed metal containers stored in a storage cabinet or in safety cans:    (a) MECHANICS SHOP: Flammable materials were not stored in a flammable cabinet, exposing employees to fire hazards.
Recent events (2)
  • · I (S) $1670
  • · Z (S) $3326

1910.106 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 28, 2018
Abate by
Dec 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.106(f)(6): "No Smoking" signs were not conspicuously posted where hazard from flammable liquid vapors is normally present.  (a) MECHANICS SHOP:  No smoking signs were not posted in areas where flammable materials were stored, exposing employees to fire hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.151 C

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 28, 2018
Abate by
Dec 24, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) Mechanics Shop- No eyewash was available near a battery charging area and where corrosives were used, exposing employees to hazards from chemical splashes. Chemicals observed onsite included brake cleaner, acid batteries, glass cleaner, industrial cleaner, aerosolized paints and primers.
Recent events (2)
  • · I (S) $1663
  • · Z (S) $1663

1910.1200 E01

Serious Gravity 1 1 instance 10 exposed
Issued
Nov 28, 2018
Abate by
Dec 24, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:(a)  (a) Facility wide- The employer had not written or developed a hazard Communication Program, exposing workers to hazards from contact with chemical.
Recent events (2)
  • · I (S) $1663
  • · Z (S) $1663

1910.1200 G01

Serious Gravity 1 1 instance 9 exposed
Issued
Nov 28, 2018
Abate by
Dec 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: (a) Plant Wide- The employer had not have safety data sheets for chemicals used in the workplace, exposing employee to hazards from contact with chemicals.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H02

Serious Gravity 1 1 instance 9 exposed
Issued
Nov 28, 2018
Abate by
Dec 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(2): The employer did not provide employees with effective information on hazardous chemicals in their work area at the time of their initial assignment and whenever a new chemical hazard the employees have not previously been trained about was introduced into their work area. Employees were not informed of the following: the requirements of this section; any operations in their work area where hazardous chemicals are present; and, the location and availability of the written hazard communication program, including the required list(s) of hazardous chemicals, and safety data sheets as required by this section.  (a) The employer had not trained his employees on the chemicals used in the workplace, exposing employee to hazards from contact with chemicals.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H03

Serious Gravity 1 1 instance 9 exposed
Issued
Nov 28, 2018
Abate by
Dec 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv):  (a) The employer had not trained his employees on the chemicals used in the workplace, exposing employee to hazards from contact with chemicals.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 F01

Serious Gravity 1 1 instance 9 exposed
Issued
Nov 28, 2018
Abate by
Dec 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(1): The chemical manufacturer, importer, or distributor did not ensure that each container of classified hazardous chemicals leaving the workplace was labeled, tagged or marked with the information required in 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(vi)  (a) Mechanic Area- Two 50 gallon barrels of liquid were not marked to indicate the contents, exposing employee to hazards from contact with unknown chemicals.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Owan, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343561544.