Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: REGAL BELOIT AMERICA, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of REGAL BELOIT AMERICA, INC. in 6801 SOUTH BENTSEN ROAD, MCALLEN, TX 78503 (NAICS 335312). OSHA activity number 343563276.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Regal Beloit America, INC. for free Get an email when a new federal OSHA severe-injury report for Regal Beloit America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6801 SOUTH BENTSEN ROAD
City
MCALLEN
State
TX
ZIP
78503
Mailing
6801 SOUTH BENTSEN ROAD, MCALLEN, TX 78503
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
335312
Employees
240
Ownership type
Private (A)

7 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 20 exposed
Issued
Apr 19, 2019
Penalty
Initial $8,856 · Current $8,856
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  At this facility, employees were exposed to corrosive materials and aluminum dust while manufacturing aluminum parts, and were not provided with an eye wash station or other suitable means of quick drenching.
Recent events (2)
  • · C (S) $8856
  • · Z (S) $8856

1910.305 G01 IV A

Serious Gravity 1 2 instances 20 exposed
Issued
Apr 19, 2019
Penalty
Initial $5,314 · Current $5,314
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  At this facility, employees were exposed to electrical hazards when utilizing extension cords and/or relocatable power taps to power equipment in the following instances:  a.  AD #6, a Q Standard industrial fan was plugged into a relocatable power tap that was plugged into an extension cord which was plugged into the fixed electrical outlet; and,  b.  Tool room, a small hoist was plugged into extension cord which was plugged into the fixed electrical outlet.
Recent events (2)
  • · C (S) $5314
  • · Z (S) $5314

1910.334 A02 I

Serious Gravity 1 2 instances 8 exposed
Issued
Apr 19, 2019
Penalty
Initial $5,314 · Current $5,314
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  At this facility, in the end shield die cast (ESDC) areas, employees were exposed to electrical hazards in the following instances:  a.  Damaged extension cord used to operate the Q Standard industrial floor fan; and,  b.  The plug for the Q Standard industrial floor fan was missing the ground prong.
Recent events (2)
  • · C (S) $5314
  • · Z (S) $5314

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Apr 19, 2019
Abate by
Apr 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   At this establishment, the employer did not review and/or update the lockout/tagout (Control of Hazardous Energy) procedures annually to ensure proper energy isolation.
Recent events (2)
  • · C (O) $0
  • · Z (O) $0

1910.305 B01 II

Other-than-serious 4 instances 8 exposed
Issued
Apr 19, 2019
Abate by
Apr 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  In the tool room, electrical boxes had unused openings on the underside of the boxes in the following instances:  a.  600 volt electrical box adjacent to entrance door into tool room and adjacent to fire extinguisher #30; b.  Square D safety switch mounted on the Lodge & Shipley Blue Chip with serial number 27081;  c.  480 volt electrical box with a ML placard on the front panel; and, d.  Junction box adjacent to PW #2-FUG.
Recent events (2)
  • · C (O) $0
  • · Z (O) $0

1910.1200 E01 I

Other-than-serious 2 instances 20 exposed
Issued
Apr 19, 2019
Abate by
Apr 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet:  At this establishment, the hazard communication program did not contain an updated chemical inventory list of the chemicals present in the employees' work areas in the following instances:  a.  Aluminum Unalloyed Metal Ingot, PXXXX, AAXXX Series (primary aluminum ingots); and, b.  Secondary Aluminum Alloys - Ingot, Sow or Molten (secondary aluminum ingots).
Recent events (2)
  • · C (O) $0
  • · Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 4 exposed
Issued
Apr 19, 2019
Abate by
Apr 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  At this facility, employees use and are exposed to hazardous chemicals prior to receiving training on those chemicals.
Recent events (2)
  • · C (O) $0
  • · Z (O) $0

View Regal Beloit America, INC.'s full OSHA safety record →