JACKSONVILLE, FL —
OSHA Inspection: CITY ELECTRIC SUPPLY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CITY ELECTRIC SUPPLY in 4601 BULLS BAY HIGHWAY SUITE 203, JACKSONVILLE, FL 32219 (NAICS 444190). OSHA activity number 343583019.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CITY ELECTRIC SUPPLY
- Site address
- 4601 BULLS BAY HIGHWAY SUITE 203
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32219
- Mailing
- 4601 BULLS BAY HIGHWAY SUITE 203, JACKSONVILLE, FL 32219
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 24
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A03 II
- Issued
- Jan 9, 2019
- Abate by
- Mar 1, 2019
- Penalty
- Initial $10,365 · Current $5,183 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about November 6, 2018, on the Reel Power NK6 machine, an employee feeding wire at the roller guide was exposed to caught-in and amputation hazard while putting his hand on the point of operation. b. On or about November 6, 2018, on the Reel Power NK6 machine, an employee feeding wire at the reel was exposed to caught-in and amputation hazard while putting his hand on the point of operation.
Recent events (2)
- — I (O) $5182.5
- — Z (S) $10365
More inspections at City Electric Supply
View City Electric Supply's full OSHA safety record →
More inspections in this industry (NAICS 444190)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343583019.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.