On , OSHA opened a planned safety inspection of OLSON CONSTRUCTION LLC in 2109 FOXHALL RD NW, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 343591764.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OLSON CONSTRUCTION LLC
- Site address
- 2109 FOXHALL RD NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 18302 POPLAR STAND PL, PURCELLVILLE, VA 20132
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 7
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Feb 7, 2019
- Abate by
- Feb 13, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about November 8, 2018; roof area of new edition; employees were walking the top-plate without fall protection in place to protect them from falling 30-feet to ground level. b) On or about November 8, 2018; second floor; employees were working near floor openings such as but not limited to a stair opening that was not guarded, exposing them to a 10-foot fall to the lower level. c) On or about November 8, 2018; second-floor area; employees were working near unguarded wall openings, exposing them to a 20-foot fall to ground level; while framing. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3978
1926.1053 B01
- Issued
- Feb 7, 2019
- Abate by
- Feb 13, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access. a) On or about November 8, 2018; Second-floor area; Employees used an 8-foot step ladder to access the roof/top plate, which was 4-feet below the platform, exposing employees to a potential 10-foot fall to the lower wood floor or 20-foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3978
1926.1053 B13
- Issued
- Feb 7, 2019
- Abate by
- Feb 13, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about November 8, 2018; second-floor area; employees used an 8- foot step-ladder, which was too short, to access the roof/top-plate area, located 10-feet above the floor, exposing them to a fall hazard when using the top-step of the ladder. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.503 B01
- Issued
- Feb 7, 2019
- Abate by
- Feb 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about November 8, 2018; throughout the site; the employer had not certified the fall protection training provided to employees who may be exposed to fall hazards 6-feet or greater In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (O) $0
More inspections at Olson Construction LLC
View Olson Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343591764.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.