BURLESON, TX —
OSHA Inspection: THE BURLY CORPORATION OF NORTH AMERICA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE BURLY CORPORATION OF NORTH AMERICA in 754 N. BURLESON BLVD, BURLESON, TX 76028 (NAICS 332618). OSHA activity number 343593224.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE BURLY CORPORATION OF NORTH AMERICA
- Site address
- 754 N. BURLESON BLVD
- City
- BURLESON
- State
- TX
- ZIP
- 76028
- Mailing
- 754 N. BURLESON BLVD, BURLESON, TX 76028
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 23
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 D01
- Issued
- Dec 3, 2018
- Abate by
- Jan 2, 2019
- Penalty
- Initial $1,885 · Current $1,131 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which were not supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. At the break room area, the employer stored materials above the office without a load rating or a sign indicating the approved load limit exposing employees to struck-by or crushed-by hazards.
Recent events (2)
- — I (S) $1131
- — Z (S) $1885
1910.23 E01
- Issued
- Dec 3, 2018
- Abate by
- Jan 2, 2019
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. At the warehouse shipping office, the stairway had a guardrail that consisted of a top rail and post but did not have the intermediate rail exposing employees to fall hazards.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.37 A03
- Issued
- Dec 3, 2018
- Abate by
- Jan 2, 2019
- Penalty
- Initial $1,885 · Current $1,131 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed. Next to the shipping office, the path to the exit door was blocked by a rack with merchandise stored on the rack and on the floor around it exposing employees to tripping and entrapment hazards.
Recent events (2)
- — I (S) $1131
- — Z (S) $1885
1910.37 B02
- Issued
- Dec 3, 2018
- Penalty
- Initial $1,885 · Current $1,131 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit". On the south east side of the warehouse, the employer did not ensure exit doors were marked with an "EXIT" sign exposing employees to fire and smoke hazards.
Recent events (2)
- — I (S) $1131
- — Z (S) $1885
1910.101 B
- Issued
- Dec 3, 2018
- Penalty
- Initial $2,513 · Current $1,508 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6. In the welding shop, compress gas cylinders were not chained or secured from falling exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $1507.8
- — Z (S) $2513
1910.215 A04
- Issued
- Dec 3, 2018
- Penalty
- Initial $2,513 · Current $1,508 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work. Bench grinders used by employees were not equipped with work rests exposing employees to caught-in and struck-by hazards. The employer did not ensure all equipment used to aid in shaping and/or grinding material was inspected: a) In the welding shop, RYOBI bench grinder was used without work rests, b) In the maintenance shop, bench grinder was used without work rests.
Recent events (2)
- — I (S) $1507.8
- — Z (S) $2513
1910.215 B09
- Issued
- Dec 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. The employer did not ensure adjustable tongue guards were installed and used prior to operating grinders, exposing employees to struck-by flying objects: a) In the welding shop, RYOBI bench grinder was used without tongue guards, b) In the maintenance shop, bench grinder was used without tongue guards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Dec 3, 2018
- Penalty
- Initial $2,513 · Current $1,508 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed. In the re-roll machine area, there was not a guard covering the 19 inch chain, and the 1/2 inch and 5 1/2 sprockets on the re-roll machine exposing employees to hazards of being caught-in chain and sprockets.
Recent events (2)
- — I (S) $1507.8
- — Z (S) $2513
1910.303 E
- Issued
- Dec 3, 2018
- Penalty
- Initial $1,885 · Current $1,131 Reduced
General-duty citation text
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary. In the shop areas, the employer had electrical panel boxes that energize lights and machinery which were not marked with voltage ratings: a) In the warehouse area, panel box east side. b) In the shipping area, panel box west side.
Recent events (2)
- — I (S) $1131
- — Z (S) $1885
More inspections at The Burly Corporation of North America
View The Burly Corporation of North America's full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343593224.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.