FRANKLIN, PA ·
OSHA Inspection: VENANGO STEEL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VENANGO STEEL, INC. in 1655 PITTSBURGH ROAD, FRANKLIN, PA 16323 (NAICS 332999). OSHA activity number 343594990.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VENANGO STEEL, INC.
- Site address
- 1655 PITTSBURGH ROAD
- City
- FRANKLIN
- State
- PA
- ZIP
- 16323
- Mailing
- 1655 PITTSBURGH ROAD, FRANKLIN, PA 16323
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 25
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.147 C04 II
- Issued
- May 9, 2019
- Abate by
- Jun 17, 2019
- Penalty
- Initial $3,031 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, items A through D of this section: a) Production area, on or about November 9, 2018, a specific energy control procedures (lockout tagout procedure) were not developed and documented for the machines that included but were not limited to the press brake, plasma and laser tables. The only procedure for the machines was a generic procedure that did not contain the specific methods, techniques, and procedural elements outlined in 29 CFR 1910.147(c)(4)(ii)(A) through 29 CFR 1910.147(c)(4)(ii)(D)
Recent events (2)
- · I (S) $1500
- · Z (S) $3031
1910.147 C06 I
- Issued
- May 9, 2019
- Abate by
- Jun 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: a) Production area, on or about November 9, 2018, employees conducted servicing and maintenance work on machines that included but were not limited to the press brake, plasma and laser tables. Annual periodic inspections of the lockout/tagout procedures (energy control procedures) had not been conducted.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 A04
- Issued
- May 9, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $2,273 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval. Capacity, operation, and maintenance instruction plates, tags or decals of the powered industrial truck were not changed accordingly: a.) Venango Steel, Inc. in Franklin, PA. On or about November 9, 2018, fork extensions were utilized on the Hyster forklift truck. Approval from the manufacturer for the forklift attachment was not obtained. In addition, the capacity plate on the forklift was not modified to reflect the effects on the capacity of the forklift when the attachment was used.
Recent events (2)
- · I (S) $1800
- · Z (S) $2273
1910.178 A05
- Issued
- May 9, 2019
- Abate by
- Jul 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5): When the truck was equipped with front-end attachments other than factory installed attachments, the user did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: a.) Venango Steel, Inc. in Franklin, PA. On or about November 9, 2018, fork extensions were utilized on the Hyster forklift truck. Approval from the manufacturer for the forklift attachment was not obtained. In addition, the capacity plate on the forklift was not modified to reflect the effects on the capacity of the forklift when the attachment was used.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 P01
- Issued
- May 9, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $2,273 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): When a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck was not taken out of service until it was restored to safe operating condition: a) Production area, on or about November 9, 2018, the tires on the Hyster forklift were significantly damaged in that they were missing large chunks. The Hyster forklift remained in operation with damaged tires.
Recent events (2)
- · I (S) $1500
- · Z (S) $2273
1910.212 A01
- Issued
- May 9, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $3,031 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, moving parts, flying chips and sparks: a) Venango Steel, Inc., on or about November 9, 2018, the unused portion of the blade and the blade guide wheels on the Roll-In Vertical Band Saw were not guarded.
Recent events (2)
- · I (S) $2000
- · Z (S) $3031
1910.303 B02
- Issued
- May 9, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $2,273 · Current $1,060 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Venango Steel, Inc. in Franklin, PA. On or about November 9, 2018, a household style box fan was used by employees for cooling. The household style box fan was not listed and labeled for use in the industrial work environment.
Recent events (2)
- · I (S) $1060
- · Z (S) $2273
More inspections at Venango Steel, INC.
View Venango Steel, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343594990.