Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TIGERPOLY MANUFACTURING, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TIGERPOLY MANUFACTURING, INC. in 6231 ENTERPRISE PARKWAY, GROVE CITY, OH 43123 (NAICS 326199). OSHA activity number 343599254.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tigerpoly Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Tigerpoly Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6231 ENTERPRISE PARKWAY
City
GROVE CITY
State
OH
ZIP
43123
Mailing
6231 ENTERPRISE PARKWAY, GROVE CITY, OH 43123
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
400
Ownership type
A

6 citations on file for this inspection.

1910.107 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 6, 2019
Abate by
Mar 13, 2019
Penalty
Initial $9,472 · Current $5,210 Reduced

Hazardous substances 108024602590

29 CFR 1910.107(b)(1): Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.   a. On and/or before November 28, 2018, the spray booth used by employees while spraying Per-Fix Black Polypropylene TPO (Product No. 7500A) onto molded plastic parts was constructed of a framed canvas material and not of steel, concrete or masonry, aluminum, or other substantial noncombustible material.
Recent events (2)
  • — I (S) $5209.6
  • — Z (S) $9472

1910.107 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 6, 2019
Abate by
Mar 13, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 108024602590

29 CFR 1910.107(b)(3): Floors. The floor surface of a spray booth and operator's working area, if combustible, shall be covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues.   a. On and/or before November 28, 2018, in the spray booth, the working surface used by employees while spraying Per-Fix Black Polypropylene TPO (Product No. 7500A) onto molded plastic parts was covered with combustible cardboard coated with overspray.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 6, 2019
Abate by
Mar 13, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 108024602590

29 CFR 1910.107(b)(5)(i): The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.   a. On or about November 28, 2018, the open face of the spray booth used by employees while spraying Per-Fix Black Polypropylene TPO (Product No. 7500A) onto molded plastic parts had an average air velocity of 31 linear feet per minute.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C06

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 6, 2019
Abate by
Mar 13, 2019
Penalty
Initial $9,472 · Current $5,210 Reduced

Hazardous substances 108024602590

29 CFR 1910.107(c)(6): Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.   a. On and/or before November 28, 2018, the electrical equipment including a 220 VAC receptacle, outlet box containing two 120 VAC duplex receptacles, Airrex HSC-HEPA2000 negative air machine, and light located in the spray booth used by employees while spraying Per-Fix Black Polypropylene TPO (Product No. 7500A) onto molded plastic parts was not of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations.
Recent events (2)
  • — I (S) $5209.6
  • — Z (S) $9472

1910.304 G05

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 6, 2019
Abate by
Feb 19, 2019
Penalty
Initial $9,472 · Current $5,210 Reduced
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.   a. On or about November 14, 2018, in the B01 area, the Air King 18" pedestal fan (model: SFS-450B) was not grounded due to a missing ground prong on the plug end of the cord.
Recent events (2)
  • — I (S) $5209.6
  • — Z (S) $9472

1910.305 G02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 6, 2019
Abate by
Feb 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.   a. On or about November 14, 2018, in the B01 area, the flexible cord used to power the Air King 18" pedestal fan (model: SFS-450B) was not provided with strain relief and was damaged at the plug end of the cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Tigerpoly Manufacturing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343599254.