LIVERPOOL, NY —
OSHA Inspection: PAUL DELIMA CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PAUL DELIMA CO., INC. in 7546 MORGAN ROAD, LIVERPOOL, NY 13090 (NAICS 493110). OSHA activity number 343601662.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PAUL DELIMA CO., INC.
- Site address
- 7546 MORGAN ROAD
- City
- LIVERPOOL
- State
- NY
- ZIP
- 13090
- Mailing
- 7546 MORGAN ROAD, LIVERPOOL, NY 13090
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 44
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Nov 26, 2018
- Abate by
- Dec 14, 2018
- Penalty
- Initial $4,398 · Current $2,639 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Maintenance Dept., on or about 11/15/18: Rotating chuck on a Craftsman drill press was not provided with a guard. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2638.8
- — Z (S) $4398
1910.212 B
- Issued
- Nov 26, 2018
- Abate by
- Dec 14, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Maintenance Dept., on or about 11/15/18: A Craftsman drill press was not secured to prevent walking or moving. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Nov 26, 2018
- Abate by
- Dec 14, 2018
- Penalty
- Initial $3,298 · Current $1,979 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Packaging Dept., on or about 11/15/18: Compressed air gun at Packaging Line #10 measured 90 psi. b) Packaging Dept., on or about 11/15/18: Compressed air gun at Packaging Line #9 measured 70 psi. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1978.8
- — Z (S) $3298
1910.305 G01 IV A
- Issued
- Nov 26, 2018
- Abate by
- Dec 31, 2018
- Penalty
- Initial $3,298 · Current $1,979 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Packaging Dept., on or about 11/15/18: Extension cord providing current to a switch for the filler on Hand Pack Line 13 was being used as permanent wiring. b) Packaging Dept., on or about 11/15/18: Extension cords providing current to two scales on Packaging Line 11 were being used as permanent wiring. c) Packaging Dept., on or about 11/15/18: Extension cord providing current to the conveyor and scale on Packaging Line 8 was being used as permanent wiring. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1978.8
- — Z (S) $3298
1910.147 C04 I
- Issued
- Nov 26, 2018
- Abate by
- Dec 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the establishment, on or about 11/15/18: Where employees perform servicing and/or maintenance on various machinery or equipment, including, but not limited to 12 packaging lines, air compressors, etc., the employer had not established specific energy control procedures to prevent the unexpected energizing, start up or release of stored energy of the equipment. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Paul Delima CO., INC.
View Paul Delima CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343601662.