ENGLEWOOD, CO —
OSHA Inspection: GLAZ-TECH INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GLAZ-TECH INDUSTRIES, INC. in 4005 S. CLAY ST., ENGLEWOOD, CO 80111 (NAICS 327215). OSHA activity number 343606026.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLAZ-TECH INDUSTRIES, INC.
- Site address
- 4005 S. CLAY ST.
- City
- ENGLEWOOD
- State
- CO
- ZIP
- 80111
- Mailing
- 2207 E ELVIRA ROAD, TUCSON, AZ 85756
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327215
- Employees
- 46
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.28 B01 I
- Issued
- Jan 17, 2019
- Penalty
- Initial $7,391 · Current $4,435 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system: (a) On or about November 15, 2018, and at times prior, employees were exposed to a fall hazard of 12 feet and 9 inches, from the ladder entrance to the storage area above the shop floor along the west wall.
Recent events (2)
- — I (S) $4435
- — Z (S) $7391
1910.147 C04 II D
- Issued
- Jan 17, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $5,543 · Current $3,326 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: (a) On or about November 15, 2018, and at times prior employees were potentially exposed to hazardous energy because the procedures to isolate machines from hazardous energy did not include specific steps to test the machines and verify that the energy control measures were effective. The incomplete procedures included, but were not limited to those for the following machines: seamers in the cutting line; bevelers in the flat line (Max 80 CNC Bavelloni and Elettromeccanica Bouone); Billco washers at the cutting line and in the insulated glass area; and power grinder #13 in the polishing area. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $3326
- — Z (S) $5543
1910.147 C06 I
- Issued
- Jan 17, 2019
- Abate by
- Mar 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On or about November 15, 2018, and at times prior employees were potentially exposed to hazardous energy because the employer did not inspect, nor certify, the sufficiency of the Glaz-Tech Industries lockout/tagout procedures at least annually with the purpose of ensuring that the procedure is sufficient, and that the authorized personnel are following it properly. Abatement Note: The periodic inspection shall be performed by an authorized employee other than the one(s) utilizing the energy control procedure being inspected (29 CFR 1910.147(c)(6)(I)[A]). The employer shall certify that the periodic inspections have been performed by documenting the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection (29 CFR 1910.147(c)(6)(ii)). Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Jan 17, 2019
- Abate by
- Mar 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) On or about November 15, 2018, and at times prior, the authorized employee was potentially exposed to hazardous energy because he was not trained on the Glaz-Tech Hazardous Energy Control program and the procedures that he was expected to utilize. Abatement Note: In addition to each authorized employee, affected employees shall be instructed in the purpose and use of the energy control procedures (29 CFR 1910.147(c)(7)(i)[B]); and other employees whose work operations are in the area where energy control procedures may be utilized, shall be instructed about the procedure(s) and the prohibition of attempting to restart or reenergize machines or equipment which are locked out or tagged out (29 CFR 1910.147(c)(7)(i)[C]). The employer shall certify that employee training has been accomplished and is being kept up to date. The certification shall contain each employee's name and dates of training (29 CFR 1910.147(c)(7)(iv)). Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D01
- Issued
- Jan 17, 2019
- Abate by
- Mar 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(1): The authorized employee did not have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy before the authorized or affected employee turned off machines or equipment: (a) On or about November 15, 2018, and at times prior, the authorized employee was potentially exposed to hazardous energy in that he did not know the types and magnitude of energy in the machines he was required to shut down and isolate. Abatement Note: Information regarding the types and magnitude of energies must be included in authorized person training (29 CFR 1910.147(c)(7)(i)[A]), and should also be included on the machine or equipment specific procedures for controlling hazardous energy OSHA CPL 02-00-147. Chapter 3, Page 3-43) Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jan 17, 2019
- Abate by
- Feb 13, 2019
- Penalty
- Initial $5,543 · Current $3,326 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about November 15, 2018, and at times prior, employees were exposed to struck-by and caught-in hazards while operating the Intermac CNC beveler without a functioning interlock door device. (b) On or about November 15, 2018, and at times prior, workers were exposed to caught-in hazards from unguarded gears on the Belco washers in the cutting area and in the insulated glass area, above the clean and dirty water tanks. Abatement Note: Abatement certification is required for this item (see the enclosed, "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $3326
- — Z (S) $5543
1910.215 A04
- Issued
- Jan 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about November 15, 2018, and at times prior, the work rest of the Ryobi 8-inch bench grinder in the maintenance room, was not adjusted close enough to the grinding wheel, exposing employees to a caught-in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Jan 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) On or about November 15, 2018, and at times prior, the tongue guard of the Ryobi 8-inch bench grinder in the maintenance room, was missing, exposing employees to struck-by and laceration hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Jan 17, 2019
- Abate by
- Feb 6, 2019
- Penalty
- Initial $7,391 · Current $4,435 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: (a) On or about November 15, 2018, and at times prior, employees were exposed to caught-in and amputation hazards from the following unguarded chain and sprockets that move the glass tipping table in the cutting area: the blue sprocket and chain in the middle of the table that tips the table up and down. the blue sprocket and chain that drive the wheels to move glass laying on the table. (b) On or about November 15, 2018, and at times prior, employees were exposed to caught-in and amputation hazards on Bavelloni Max 80: from the unguarded chain and sprockets on the right side of the operator station near the ground at the location that a bucket is positioned to catch the ejected swarf solution. from the drive belts on on the left side of the operator station near the ground. (c) On or about November 15, 2018, and at times prior, employees were exposed to caught-in and laceration hazards from the ingoing nip point of the unguarded chain and sprocket on the right side of the Billco washer (from the glass entry end) in the insulated glass area. Abatement Note: Abatement certification is required for this item (see the enclosed, "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $4435
- — Z (S) $7391
1910.305 B01 I
- Issued
- Jan 17, 2019
- Abate by
- Feb 6, 2019
- Penalty
- Initial $5,543 · Current $3,326 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: (a) On or about November 15, 2018, and at times prior, employees were exposed to electrical hazards where rigid conduit was not properly connected and the electrical wires inside were exposed: 1) The pull box for the wires that powered the outlet to which the retractable extension cord was connected in the cutting area, was disconnected from the outlet where it was supposed to be attached at the knockout, and the cover of the box was loose. 2) The metal clad conduit connected to the shape beveler, was broken where the electrical power is brought into the machine (note: this is a wet area). Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $3326
- — Z (S) $5543
1910.305 G02 III
- Issued
- Jan 17, 2019
- Abate by
- Feb 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) On or about November 15, 2018, and at times prior, employees were exposed to shock, burns, and fire hazards in that the insulation of flexible cords was pulled back from its connection causing strain to be placed on the live conductors in the following locations: 1) Insulation on the retractable extension cord on the extension cord into which the Makita hand held grinder in the cutting area was plugged, was separated from the plug; 2) Insulation on plug of the extension cord powering the relocatable power taps at the cutting table. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Jan 17, 2019
- Abate by
- Feb 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: (a) On or about November 15, 2018, and at times prior, employees were exposed hazards from electrical cords of energized equipment that employees were using, which had ripped and torn insulation, exposing the conductors inside: 1) falling object and laceration hazards were the power to be interrupted; the electrical cord powering the suction cup vacuum hoist on the 5 ton Wazee crane used to move raw glass in the receiving area had ripped and torn insulation and potentially damaged conductors inside. 2) shock, burn and fire from the retractable extension cord powering the Makita hand held grinder in the cutting area, which had ripped and torn insulation exposing the conductors inside, and was missing the grounding prong. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Jan 17, 2019
- Abate by
- Feb 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about November 15, 2018, and at times prior, employees were exposed to shock, electrocution, fire and burns from relocatable power taps (RPT) at the cutting table. Two RPTs were plugged into each other and powered by an extension cord (the system was daisy chained). The RPTs powered the computer for the cutting table. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01 I
- Issued
- Jan 17, 2019
- Abate by
- Feb 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet: (a) On or about November 15, 2018, and at times prior, the employer did not maintain a list of hazardous chemical known to be in use at the workplace. The missing chemicals included, but were not limited to: ACECUT 5503 (lung damage); Kommerling 3070 High Strength Single Seal IG Hot Melt (may cause an allergic skin reaction) Abatement Note: The list must include a product identifier for each chemical on the chemical inventory so that readers can accurately cross reference each with its safety data sheet. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Glaz-Tech Industries, INC.
View Glaz-Tech Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327215)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343606026.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.