OSHA Inspection: MCCOY CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MCCOY CORPORATION in 9001 GATEWAY BLVD. SOUTH, EL PASO, TX 79904 (NAICS 444190). OSHA activity number 343614939.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mccoy Corporation — free Get an email when a new federal OSHA severe-injury report for Mccoy Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
MCCOY CORPORATION
Site address
9001 GATEWAY BLVD. SOUTH
City
EL PASO
State
TX
ZIP
79904
Mailing
1350 IH-35 NORTH, SAN MARCOS, TX 78666
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
22
Ownership type
A

2 citations on file for this inspection.

1910.303 G02 I D

Other-than-serious 6 instances 2 exposed
Issued
Jan 25, 2019
Abate by
Mar 8, 2019
Penalty
Initial $5,115 · Current $5,000 Reduced
29 CFR 1910.303(g)(2)(i)(D): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by elevation of 2.44 m (8.0 ft) or more above the floor or other working surface:    On or about November 21, 2018, employees working on or accessing the store mezzanine were exposed electrical shock hazards from unprotected light fixtures that were less than 8 feet from the mezzanine floor.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $5115

1910.303 G02 II

Other-than-serious 4 instances 2 exposed
Issued
Jan 25, 2019
Abate by
Mar 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:    On or about November 21, 2018, employees who work on the store mezzanine were exposed to fluorescent light tubes that were not guarded against physical damaged and their height from the mezzanine floor was approximate six feet, exposing employees to struck-by hazards.