BROOKLYN, NY —
OSHA Inspection: VESCOM SYSTEMS, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of VESCOM SYSTEMS, LLC in 859 MYRTLE AVE., BROOKLYN, NY 11206 (NAICS 238190). OSHA activity number 343617254.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VESCOM SYSTEMS, LLC
- Site address
- 859 MYRTLE AVE.
- City
- BROOKLYN
- State
- NY
- ZIP
- 11206
- Mailing
- 100 3RD AVE., KEARNY, NJ 07032
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 16
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.602 C01 II
- Issued
- May 20, 2019
- Abate by
- May 31, 2019
- Penalty
- Initial $10,210 · Current $10,210
General-duty citation text
29 CFR 1926.602(c)(1)(ii): Modifications or additions which affect the capacity or safe operation of the equipment were made without the manufacturer's written approval. a) 4th floor: A forklift stacker was used with a shorty lift boom attached to the fork blades for moving and installing wall panels. But the capacity, operation, and maintenance instruction plates, tags, or decals were not changed before using the affected forklift. The addition of using a lift boom affects the lift capacity and safe operation of the forklift stacker, and the lift boom was used without the forklift stacker manufacturer's written approval. On or about 11/21/18.
Recent events (3)
- — F (S) $10210
- — C (S) $10210
- — Z (S) $10210
1926.602 C01 VI
- Issued
- May 20, 2019
- Abate by
- May 28, 2019
- Penalty
- Initial $10,210 · Current $10,210
General-duty citation text
29 CFR 1926.602(c)(1)(vi): Industrial truck(s) in use did not meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standards for Powered Industrial Trucks. a) 4th floor: A forklift stacker was used with a shorty lift boom attached to the fork blades for moving and installing wall panels. Employees operated the forklift in high wind condition to lift a panel that is about 15 feet by 10 feet. The forklift overturned and the wall panel toppled on top of an employee during panel lifting under these conditions. On or about 11/21/18.
Recent events (3)
- — F (S) $10210
- — C (S) $10210
- — Z (S) $10210
1926.602 C01 VII
- Issued
- May 20, 2019
- Abate by
- May 28, 2019
- Penalty
- Initial $10,210 · Current $10,210
General-duty citation text
29 CFR 1926.602(c)(1)(vii): A safe place to ride forklift trucks was not provided where riding of trucks is authorized. a) 4th floor: A forklift stacker was used with a shorty lift boom attached to the fork blades for moving and installing wall panels. An employee was instructed to ride on the forklift stacker to act as additional counterweight for lifting the panel walls. A safe place to ride the forklift stacker was not provided, and the employee was thrown off the forklift when it overturned while lifting a wall panel. On or about 11/21/18.
Recent events (3)
- — F (S) $10210
- — C (S) $10210
- — Z (S) $10210
1926.602 D
- Issued
- May 20, 2019
- Abate by
- May 31, 2019
- Penalty
- Initial $10,210 · Current $10,210
General-duty citation text
29 CFR 1926.602(d): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l), as referenced to 29 CFR 1910.178(l)(1)(i). Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178. a) 4th floor: A forklift stacker was used with a shorty lift boom attached to the fork blades for moving and installing wall panels. The employer did not evaluate, train, test, or certify the forklift stacker operator to ensure that he is competent to operate a forklift stacker safely. On or about 11/21/18.
Recent events (3)
- — F (S) $10210
- — C (S) $10210
- — Z (S) $10210
1926.760 D01
- Issued
- May 20, 2019
- Abate by
- May 28, 2019
- Penalty
- Initial $10,210 · Current $10,210
General-duty citation text
29 CFR 1926.760(d)(1): Personal fall arrest systems, positioning device systems and their components were not conform to the criteria in �� 1926.502 (see Appendix G to this subpart). a) 4th floor: Employees were installing wall panels at the edge of the building. One employee was tied off to a wall panel lying on the floor as a fall arrest anchor while removing guardrails from the edge of the building. The wall panel on the floor was not structurally secured and was not conform to the criteria of a fall arrest anchor. On or about 11/21/18.
Recent events (3)
- — F (S) $10210
- — C (S) $10210
- — Z (S) $10210
1926.760 A01
- Issued
- May 20, 2019
- Abate by
- May 28, 2019
- Penalty
- Initial $20,420 · Current $20,420
General-duty citation text
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who was on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. a) 4th floor: Employee were installing wall panels at the edge of the building without fall protection. Guardrails were removed from the edge of the building and employees were not tied off to fall arrest anchors during the installation process. On or about 11/21/18. Vescom Systems, LLC was previously cited for a violation of an equivalent Occupational Safety and Health Standard 29 CFR 1926.501(b)(1), which was contained in OSHA inspection number 1200138, citation number 1, item number 2 and was affirmed as a final order on 04/18/17, with respect to a workplace located at Villa BXV Kensington & Sagamore Rd, Bronxville, NY 10708.
Recent events (3)
- — F (R) $20420
- — C (R) $20420
- — Z (R) $20420
More inspections at Vescom Systems, LLC
View Vescom Systems, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343617254.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.