MARINETTE, WI —
OSHA Inspection: TYCO FIRE PRODUCTS, LP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TYCO FIRE PRODUCTS, LP in 1 STANTON ST., MARINETTE, WI 54143 (NAICS 333999). OSHA activity number 343623963.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TYCO FIRE PRODUCTS, LP
- Site address
- 1 STANTON ST.
- City
- MARINETTE
- State
- WI
- ZIP
- 54143
- Mailing
- 1 STANTON ST., MARINETTE, WI 54143
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 475
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- May 7, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $4,831 · Current $4,831
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: a) On or about November 28, 2018, the employer's Lockout Tagout Program did not include the method to ensure energy control procedures and the requirements of 29 CFR 1910.147 are being followed at least annually.
Recent events (2)
- — I (S) $4831
- — Z (S) $4831
1910.147 C04 II B
- Issued
- May 7, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $8,051 · Current $4,831 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to , the following: Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a) On or about November 28, 2018, the Lockout / Tag Out Instructions for the Redline Seam Welder (A20295), dated October 17, 2018, did not include instructions for removing pneumatic pressure from the sheet pusher air cylinder when a jammed metal sheet prevents the sheet pusher from extending completely and returning to the home position. A check valve prevents the air cylinder pneumatic pressure from bleeding off when the Main Air Supply is shut off.
Recent events (2)
- — I (S) $4831
- — Z (S) $8051
1910.147 D05 I
- Issued
- May 7, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a) On or about November 26, 2018, a Redline Fabrication Seam Welder Operator did not remove the pneumatic pressure within the sheet pusher pneumatic cylinder or return the sheet pusher to home while unjamming a metal sheet in a Seam Welder.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Tyco Fire Products, LP
View Tyco Fire Products, LP's full OSHA safety record →
More inspections in this industry (NAICS 333999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343623963.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.