PONTOTOC, MS —
OSHA Inspection: MS NONWOVENS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MS NONWOVENS, INC. in 275 INDUSTRIAL DR, PONTOTOC, MS 38863 (NAICS 313230). OSHA activity number 343644118.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MS NONWOVENS, INC.
- Site address
- 275 INDUSTRIAL DR
- City
- PONTOTOC
- State
- MS
- ZIP
- 38863
- Mailing
- 275 INDUSTRIAL DR, PONTOTOC, MS 38863
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 313230
- Employees
- 35
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 A02
- Issued
- Mar 11, 2019
- Abate by
- Apr 23, 2019
- Penalty
- Initial $5,636 · Current $5,636
General-duty citation text
29 CFR 1910.22(a)(2): (2) The floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. When wet processes are used, drainage must be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats must be provided. (a) Production Floor - On or about November 30, 2018 standing water was not maintained on the work floor. Employees were exposed to slips, trips and fall hazards. - Shipping/Receiving Area - NP4-3 Needle Press
Recent events (2)
- — I (S) $5636
- — Z (S) $5636
1910.147 C04 I
- Issued
- Mar 11, 2019
- Abate by
- Apr 2, 2019
- Penalty
- Initial $9,282 · Current $9,282
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) NP4 -3 Needle Press - On or about November 30, 2018 the employer did not have a written procedures for energy control exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing task including but not limited to servicing, maintenance and jam clearing.
Recent events (2)
- — I (S) $9282
- — Z (S) $9282
1910.147 C06 I
- Issued
- Mar 11, 2019
- Abate by
- Apr 2, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) NP4-3 Needle Press - On or about November 30, 2018 the employer had not conducted the periodic inspection of their energy control procedures to ensure they adequately identified all sources of potential hazards to employees, exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing task including but not limited to servicing, maintenance and jam clearing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Mar 11, 2019
- Abate by
- Apr 2, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees. (a) NP4-3 Needle Press - On or about November 30, 2018 the employer had not provided adequate training to the employees on the energy control program at the facility exposing employees to amputation hazards from energy sources such as but not limited to electrical and kinetic energy while performing task including but not limited to servicing, maintenance and jam clearing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at MS Nonwovens, INC.