Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: OIL STATES ENERGY SERVICES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OIL STATES ENERGY SERVICES, LLC in 405 EAST ORANGE AVE, ORANGE GROVE, TX 78372 (NAICS 213112). OSHA activity number 343651063.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch OIL States Energy Services, LLC for free Get an email when a new federal OSHA severe-injury report for OIL States Energy Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
405 EAST ORANGE AVE
City
ORANGE GROVE
State
TX
ZIP
78372
Mailing
PO BOX 1320, ORANGE GROVE, TX 78372
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
500
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C05 I

Other-than-serious 1 instance 1 exposed
Issued
Mar 15, 2019
Abate by
Apr 10, 2019
Penalty
Initial $8,051 · Current $8,051
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:     At this job site, employees performed high pressure testing on isolation valves and the job-made barrier did not provide adequate isolation nor was it adequately secured to prevent employees being struck-by the barrier, materials or debris fragments.
Recent events (2)
  • · I (O) $8051
  • · Z (S) $8051

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Mar 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  An employee conducted spray painting operations wearing a tight-fitting facepiece respirator and had not been provided an annual fit test.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View OIL States Energy Services, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343651063.