Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LINCOLN TECHNICAL INSTITUTE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LINCOLN TECHNICAL INSTITUTE, INC. in 11194 E 45TH AVE, DENVER, CO 80239 (NAICS 611519). OSHA activity number 343661617.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lincoln Technical Institute, INC. — free Get an email when a new federal OSHA severe-injury report for Lincoln Technical Institute, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11194 E 45TH AVE
City
DENVER
State
CO
ZIP
80239
Mailing
11194 E 45TH AVE, DENVER, CO 80239
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
611519
Employees
70
Ownership type
A

7 citations on file for this inspection.

1910.215 A04

Serious Gravity 1 1 instance 12 exposed
Issued
Feb 27, 2019
Abate by
Nov 5, 2019
Penalty
Initial $3,381 · Current $1,125 Reduced
29 CFR 1910.215(a)(4):  Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:       (a)   Lincoln College of Technology at 11194 E. 45th Ave., Denver, CO 80239:  On and before December 11, 2018, the employer did not ensure that the dual wheel, tungsten tip bench grinder located in the shop had the correct distance between the wheel periphery and the edge of the tool rest so that it did not exceed 1/8 inch. This condition exposed the employees to abrasion hazards to the hands.
Recent events (3)
  • — F (S) $1125
  • — C (S) $3381
  • — Z (S) $3381

1910.215 B09

Serious Gravity 1 1 instance 12 exposed
Issued
Feb 27, 2019
Abate by
Nov 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):  Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:      (a)   Lincoln College of Technology at 11194 E. 45th Ave., Denver, CO 80239:  On and before December 11, 2018, the employer did not ensure that the dual wheel, tungsten tip bench grinder located in the shop had the correct distance between the wheel periphery and the end of the peripheral member at the top so that it did not exceed ¼ inch because the adjustable tongue was missing. This condition exposed the employees to the hazard of flying chips and debris.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.254 D09 III

Other-than-serious 2 instances 12 exposed
Issued
Feb 27, 2019
Abate by
Nov 5, 2019
Penalty
Initial $3,381 · Current $1,125 Reduced
29 CFR 1910.254(d)(9)(iii):  Cables with damaged insulation or exposed bare conductors were not replaced:      (a)   Lincoln College of Technology at 11194 E. 45th Ave., Denver, CO 80239:  On and before December 11, 2018, the employer failed to provide a workplace free from recognized electrical hazards in that a welding lead located in, but not limited to, Booth #44 had damaged outer insulation that was wrapped with electrical tape instead of being replaced. This condition exposed the employees to the hazard of electrical shock.      (b)  Lincoln College of Technology at 11194 E. 45th Ave., Denver, CO 80239:  On and before December 11, 2018, the employer failed to provide a workplace free from recognized electrical hazards in that a welding lead located in, but not limited to, the plasma cutting area had damaged outer and inner insulation with exposed bare metal conductors was not replaced. This condition exposed the employees to the hazard of electrical shock.
Recent events (3)
  • — F (O) $1125
  • — C (S) $3381
  • — Z (S) $3381

1910.303 B01

Other-than-serious 2 instances 12 exposed
Issued
Feb 27, 2019
Abate by
Nov 5, 2019
Penalty
Initial $3,381 · Current $1,125 Reduced
29 CFR 1910.303(b)(1):  Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:      (a)   Lincoln College of Technology at 11194 E. 45th Ave., Denver, CO 80239:  On and before December 11, 2018, the employer failed to provide a workplace free from recognized electrical hazards in that the branch circuit wirings to duplex outlets in Booths #58 & 80 had exposed inner insulation because of damage to the wall mounted electrical boxes. This condition exposed the employees to the hazard of electrical shock.
Recent events (3)
  • — F (O) $1125
  • — C (S) $3381
  • — Z (S) $3381

1910.1200 E01

Other-than-serious 1 instance 12 exposed
Issued
Feb 27, 2019
Abate by
Nov 5, 2019
Penalty
Initial $3,381 · Current $1,125 Reduced
29 CFR 1910.1200(e)(1):  The employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):     (a)  Lincoln College of Technology at 11194 E. 45th Ave., Denver, CO 80239:  On and before December 11, 2018, the employer did not develop and implement a written hazard communication program that pertains to employee use of chemicals such as, but not limited to solvents, compressed gases, and cleansers.  This condition exposed employees to chemical hazards.
Recent events (3)
  • — F (O) $1125
  • — C (S) $3381
  • — Z (S) $3381

1910.1200 G01

Other-than-serious 1 instance 12 exposed
Issued
Feb 27, 2019
Abate by
Nov 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):  The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s):         (a)  Lincoln College of Technology at 11194 E. 45th Ave., Denver, CO 80239:  On and before December 11, 2018, the employer did not maintain safety data sheets in the workplace for chemicals such as, but not limited to solvents, compressed gases, and cleansers. This condition exposed employees to chemical hazards.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.132 D02

Other-than-serious 1 instance 5 exposed
Issued
Feb 27, 2019
Abate by
Dec 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):      (a)   Lincoln College of Technology at 11194 E. 45th Ave., Denver, CO 80239:  On and before December 11, 2018, the employer did not ensure through written verification that a workplace personal protective equipment (PPE) hazard assessment had been performed.