OSHA Inspection: UNION ELECTRIC STEEL CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of UNION ELECTRIC STEEL CORPORATION in 31 UNION ELECTRIC ROAD, BURGETTSTOWN, PA 15021 (NAICS 332111). OSHA activity number 343680278.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Union Electric Steel Corporation — free Get an email when a new federal OSHA severe-injury report for Union Electric Steel Corporation is published. One employer, no account, unsubscribe in one click.
Site address
31 UNION ELECTRIC ROAD
City
BURGETTSTOWN
State
PA
ZIP
15021
Mailing
31 UNION ELECTRIC ROAD, BURGETTSTOWN, PA 15021
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332111
Employees
120
Ownership type
A

1 citation on file for this inspection.

1910.179 L03 III

Other-than-serious 2 instances 10 exposed
Issued
Jan 10, 2019
Abate by
Jan 23, 2019
Penalty
Initial $8,315 · Current $5,000 Reduced
29 CFR 1910.179(l)(3)(iii): Repairs or replacements were not provided promptly as needed for safe operation of crane(s):         a) Melt Shop, Electric Arc Furnace, 31 Union Electric Road, Burgettstown, PA 15021:  On or about December 17, 2018, the manual magnetic disconnect on #4 crane (serial number 19065) was not promptly repaired or replaced as needed for the safe operation of the crane.  The disconnect switch was tied up in an attempt to keep it in position.   The disconnect would occasionally fall out causing the crane to loose power.          b) Melt Shop, Electric Arc Furnace, 31 Union Electric Road, Burgettstown, PA 15021:  On or about December 17, 2018, a Magnetek Impulse brand adjustable frequency crane controller located in the cab of #4 crane  (serial number 19065) was not promptly repaired or replaced as needed for the safe operation of the crane.  The unit was duct taped and a cardboard wedge was inserted into the front of the unit to keep the front panel from falling off.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $8315