Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JRS REMODELING, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JRS REMODELING, LLC in 12015 CUMMINGS HOUSE ROAD, FELTON, PA 17322 (NAICS 238160). OSHA activity number 343687208.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JRS Remodeling, LLC — free Get an email when a new federal OSHA severe-injury report for JRS Remodeling, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JRS REMODELING, LLC
Site address
12015 CUMMINGS HOUSE ROAD
City
FELTON
State
PA
ZIP
17322
Mailing
2140 GLENVIEW STREET, PHILADELPHIA, PA 19149
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 15, 2019
Abate by
Jan 28, 2019
Penalty
Initial $2,956 · Current $2,000 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) 10215 Cummings House Road - An employee cleaning up debris was exposed to struck by hazards from debris including but not limited too: shingles, roofing paper and plastic being thrown off the roof.  The employer did not ensure that the employee wore a protective helmet, on or about January 1, 2019.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2956

1926.1053 B01

Willful Gravity 5 1 instance 4 exposed
Issued
Jan 15, 2019
Abate by
Jan 28, 2019
Penalty
Initial $9,239 · Current $7,000 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    (a) 12015 Cunning House Road - Employees using a 25 foot extension ladder to gain access to the roof to install new shingles and the foreman did not ensure that the ladder extended 3 feet above the landing area, on or before January 2, 2019.     Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (W) $7000
  • — Z (W) $9239

1926.1053 B16

Other-than-serious 1 instance 5 exposed
Issued
Jan 15, 2019
Abate by
Jan 28, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.    (a) 12015 Cunning House Road - The employer did not tag out a ladder when the right foot of the ladder was defective, in that the foot was missing the rubber padding and a potion of the metal foot, on or before January 2, 2018.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View JRS Remodeling, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343687208.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.