Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HOUSTON REFINING LP

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of HOUSTON REFINING LP in 12000 LAWNDALE ST., HOUSTON, TX 77017 (NAICS 237120). OSHA activity number 343701777.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Houston Refining LP — free Get an email when a new federal OSHA severe-injury report for Houston Refining LP is published. One employer, no account, unsubscribe in one click.
Establishment
HOUSTON REFINING LP
Site address
12000 LAWNDALE ST.
City
HOUSTON
State
TX
ZIP
77017
Mailing
12000 LAWNDALE ST., HOUSTON, TX 77017
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
245
Ownership type
A

2 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 2, 2019
Abate by
Aug 19, 2019
Penalty
Initial $13,260 · Current $13,260
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    On or about January 4, 2019 at 12000 Lawndale St, Houston TX 77017, the employer did not affix Lockout and Tagout devices as required by company procedures:     a) On or about January 4, 2019, the employer did not affix a lockout device to the closed valve on the abandoned former Magellan pipe.    This condition exposed employees to flash fire hazards and struck-by hazards.
Recent events (2)
  • — I (S) $13260
  • — Z (S) $13260

1910.147 F03 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 2, 2019
Abate by
Aug 19, 2019
Penalty
Initial $13,260 · Current $13,260
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft    a) On or about January 5, 2019, at 12000 Lawndale St, Houston TX 77017, the employer did not ensure that contractors utilized group lockout on valves that Houston Refining locked out prior to demolition.
Recent events (2)
  • — I (O) $13260
  • — Z (S) $13260

View Houston Refining LP's full OSHA safety record →