Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: FISHER'S ROOFING & SIDING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FISHER'S ROOFING & SIDING, LLC in 800 BREEZY WAY, LITITZ, PA 17543 (NAICS 238170). OSHA activity number 343703112.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fisher'S Roofing & Siding, LLC — free Get an email when a new federal OSHA severe-injury report for Fisher'S Roofing & Siding, LLC is published. One employer, no account, unsubscribe in one click.
Site address
800 BREEZY WAY
City
LITITZ
State
PA
ZIP
17543
Mailing
379 SNAKE LANE, KINZERS, PA 17535
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2019
Penalty
Initial $4,168 · Current $3,126 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and a lanyard was not attached to the boom or basket while working from an aerial lift:    a) Building 800 -  Employees were observed working from a Genie S-60 aerial lift at a height of approximately 40 feet above ground and did not don a body belt (or harness) with lanyard attached to the boom or basket and were exposed to a fall hazard, on or about January 9, 2019.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $3126
  • — Z (S) $4168

1926.454 A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Abate by
Apr 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of aerial lift being used and to understand the procedures to control or minimize those hazards:   a)  Job Site - An employee working from an aerial lift was not trained in the recognition and avoidance of hazards associated with aerial lift usage, on or about January 9, 2019.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Willful Gravity 10 1 instance 1 exposed
Issued
Apr 3, 2019
Abate by
Apr 29, 2019
Penalty
Initial $58,343 · Current $34,797 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     a) Building 800 - An employee was observed installing soffit and fascia board on the roof of an apartment building and was not protected from an approximate 40 foot fall hazard to the ground below, on or about January 9, 2019.     Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (W) $34797
  • — Z (W) $58343

View Fisher'S Roofing & Siding, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343703112.