WEST MONROE, LA —
OSHA Inspection: EASON PORTABLE BUILDINGS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EASON PORTABLE BUILDINGS in 1304 NATCHITOCHES ST., WEST MONROE, LA 71292 (NAICS 332311). OSHA activity number 343704128.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EASON PORTABLE BUILDINGS
- Site address
- 1304 NATCHITOCHES ST.
- City
- WEST MONROE
- State
- LA
- ZIP
- 71292
- Mailing
- 1304 NATCHITOCHES ST., WEST MONROE, LA 71292
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332311
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 F02
- Issued
- Apr 30, 2019
- Abate by
- May 17, 2019
- Penalty
- Initial $4,546 · Current $2,728 Reduced
General-duty citation text
29 CFR 1910.178(f)(2): The storage and handling of liquefied petroleum gas fuel was not in accordance with NFPA No. 58-1969, Storage and Handling of Liquefied Petroleum Gases. Section 6.21.3.4(B): Fuel containers shall be mounted to prevent jarring loose and slipping or rotating, and the fastening shall be designed and constructed to withstand, without permanent visible deformation, static loading in any direction equal to four times the weight of the container filled with fuel: a: On or about January 10. 2019, outside the bay doors of the main shop area, the employer failed to ensure that removable LP-Gas containers were securely mounted on Yale fork lift S#B449027 to prevent displacement. b: On or about January 10. 2019, outside the bay doors of the main shop area, the employer failed to ensure that removable LP-Gas containers were securely mounted on Nissan fork lift S#95132 to prevent displacement.
Recent events (2)
- — I (S) $2727.6
- — Z (S) $4546
1910.213 C01
- Issued
- Apr 30, 2019
- Abate by
- May 17, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular hand-fed ripsaw(s) were not guarded by an automatically adjusting hood, which completely enclosed that portion of the saw above the table and above the material being cut. a) On or about January 10. 2019, inside the main shop, the employer failed to ensure that a Grizzly table saw Model #G0652 was guarded at the blade.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1910.213 C02
- Issued
- Apr 30, 2019
- Abate by
- May 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Each hand-fed circular ripsaw was not furnished with a spreader to prevent material from squeezing the saw of being thrown back on the operator: a: On or about January 10. 2019, in the main shop, the employer failed to ensure that a Grizzly table saw Model #G0652 was guarded by a spreader.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- Apr 30, 2019
- Abate by
- May 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Each hand-fed circular ripsaw was not provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a: On or about January 10. 2019, inside the main shop, the employer failed to ensure that a Grizzly table saw Model #G0652 was guarded at the blade, with nonkickback fingers or dogs.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Apr 30, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a) On or about January 10, 2019, in the shop , the employer failed to prevent employees from using plastic junction boxes rather than metal to be installed on wooden studs.
Recent events (2)
- — I (S) $3182.4
- — Z (S) $5304
1910.334 A02 I
- Issued
- Apr 30, 2019
- Penalty
- Initial $1,932 · Current $1,159 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated. a) On or about January 10, 2019, in the shop, the employer failed to prevent employees from using multiple electrical extension cords that had strain relief damage.
Recent events (2)
- — I (S) $1159.2
- — Z (S) $1932
More inspections at Eason Portable Buildings
View Eason Portable Buildings's full OSHA safety record →
More inspections in this industry (NAICS 332311)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343704128.