OSHA Inspection: BENTON FOUNDRY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BENTON FOUNDRY INC. in 5297 STATE ROUTE 487, BENTON, PA 17814 (NAICS 331511). OSHA activity number 343704771.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Benton Foundry INC. — free Get an email when a new federal OSHA severe-injury report for Benton Foundry INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BENTON FOUNDRY INC.
Site address
5297 STATE ROUTE 487
City
BENTON
State
PA
ZIP
17814
Mailing
5297 STATE ROUTE 487, BENTON, PA 17814
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
260
Ownership type
A

3 citations on file for this inspection.

1910.219 D01

Other-than-serious 1 instance 1 exposed
Issued
Mar 20, 2019
Abate by
May 6, 2019
Penalty
Initial $4,831 · Current $3,382 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a) Finishing Department: The guard on the #13 Fox snag grinder was damaged exposing the rotating power transmission pulley to contact, as observed on or about January 10, 2019.    Abatement Certification Required.
Recent events (2)
  • — I (O) $3381.7
  • — Z (S) $4831

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Mar 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment:  a) Core rigging area: The safety tip for the air wand was missing and compressed air was measured at greater than 30 p.s.i., as observed on or about January 10, 2019.  Abatement Observed During Inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.146 C07 III

Other-than-serious 4 instances 1 exposed
Issued
Mar 20, 2019
Abate by
May 6, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(7)(iii): The employer did not document the basis for determining that all hazards in a permit space had been eliminated, through a written certification that contained the date, the location of the space, and the signature of the person making the determination:  a) Melt Department: The employer did not document the reclassification of the furnaces to non-permit required confined spaces through a written certification, on or about January 22, 2019.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Benton Foundry INC.'s full OSHA safety record →