OSHA Inspection: BENTON FOUNDRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BENTON FOUNDRY, INC. in 5297 PA 487, BENTON, PA 17814 (NAICS 331511). OSHA activity number 346785751.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Benton Foundry, INC. — free Get an email when a new federal OSHA severe-injury report for Benton Foundry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5297 PA 487
City
BENTON
State
PA
ZIP
17814
Mailing
5297 PA 487, BENTON, PA 17814
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
250
Ownership type
A

4 citations on file for this inspection.

1910.29 B10

Serious Gravity 1 1 instance 95 exposed
Issued
Sep 26, 2023
Penalty
Initial $5,635 · Current $4,000 Reduced
29 CFR  1910.29(b)(10): The employer did not ensure that when guardrail systems were used at hoist areas, a removable guardrail section, consisting of a top rail and midrail, was placed across the access opening between guardrail sections when employees are not performing hoisting operations. The employer may use chains or gates instead of a removable guardrail section at hoist areas if the employer demonstrates the chains or gates provide a level of safety equivalent to guardrails:  (a) Grinding Department - Employees working from the operator platform and hoist area for TMB03 and TMB04 were exposed to a fall hazard of approximately five and a half (5.5) feet in that chain system did not protect to an adequate height (34.5 inches of a required 42+/-3 inches) and was lacking guarding on the west end of the platform, on or about June 22, 2023.  (b) Grinding Department - Employees working from the operator platform and hoist area for TMB03 and TMB04 were exposed to a fall hazard of approximately five and a half (5.5) feet in that the chain system did not cover the west end of the platform, on or about June 22, 2023  Certification Not Required.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5635

1910.36 G02

Deleted Serious Gravity 1 2 instances 80 exposed
Issued
Sep 26, 2023
Penalty
Initial $5,635 · Current $0 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:  (a) Molding Department - Employees working near molding machines HNB01 and HNB02 were exposed to fire hazards in that the emergency exit route was not at least twenty-eight (28) inches wide at all points, on or about June 22, 2023.  (b) Molding Department - Employees working near molding machines DISA 1 and DISA 2 were exposed to fire hazards in that the emergency exit route was not at least twenty-eight (28) inches wide at all points, on or about June 22, 2023.  Certification Not Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5635

1910.213 I01

Serious Gravity 5 2 instances 40 exposed
Issued
Sep 26, 2023
Penalty
Initial $9,393 · Current $6,500 Reduced
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:  (b) Pattern Shop - Employees using the Delta 28-348F (SAW78) vertical bandsaw were exposed to amputation hazards in that the adjustable guard did not fully cover both sides of the unused portion of the blade, on or about June 22, 2023.  Certification Not Required.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $9393

1910.242 B

Other-than-serious 1 instance 194 exposed
Issued
Sep 26, 2023
Abate by
Oct 6, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes:  (a) Pattern Shop - Employees using compressed air to clean equipment and products are exposed to struck-by hazards in that the air nozzles are not equipped with effective chip guarding, on or about June 22, 2023.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Benton Foundry, INC.'s full OSHA safety record →