FAIRBORN, OH ·
OSHA Inspection: ADVANCED ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANCED ROOFING LLC in 112 E. XENIA DRIVE, FAIRBORN, OH 45324 (NAICS 238160). OSHA activity number 343712170.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED ROOFING LLC
- Site address
- 112 E. XENIA DRIVE
- City
- FAIRBORN
- State
- OH
- ZIP
- 45324
- Mailing
- 7743 DARBY CREEK ROAD, ORIENT, OH 43146
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Apr 3, 2019
- Abate by
- Apr 22, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. On January 11, 2019, at 112 E. Xenia Drive, Fairborn, a two-story home, two employees were exposed to a 12 ft. fall hazard while installing weather/vapor barrier on wall of home on a 2/12 pitch roof over the porch area of the home without utilizing any fall protection.
Recent events (1)
- · Z (S) $2842
1926.502 A02
- Issued
- Apr 3, 2019
- Abate by
- Apr 22, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection. On January 11, 2019, at 112 E. Xenia Drive, Fairborn, a two-story home, the employer did not provide and install fall protection systems prior to starting work of installing weather/vapor proof and siding on the wall of the home while on the porch roof overhang, exposing employees to an approximate 12 ft. fall hazard.
Recent events (1)
- · Z (S) $2842
1926.1053 B01
- Issued
- Apr 3, 2019
- Abate by
- Apr 15, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On January 11, 2019, at 112 E. Xenia Drive, Fairborn, a two-story home, an employee was exposed to a 12 ft. fall hazard due to the aluminum extension ladder used to ascend to the porch roof overhang and descend to the ground was approximately only 24 inches above the upper landing surface.
Recent events (1)
- · Z (S) $2842
More inspections at Advanced Roofing LLC
View Advanced Roofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343712170.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.