Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FERMIN GARCIA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FERMIN GARCIA in 408 CONCORD STREET, ALPHARETTA, GA 30009 (NAICS 238130). OSHA activity number 343716130.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fermin Garcia — free Get an email when a new federal OSHA severe-injury report for Fermin Garcia is published. One employer, no account, unsubscribe in one click.
Establishment
FERMIN GARCIA
Site address
408 CONCORD STREET
City
ALPHARETTA
State
GA
ZIP
30009
Mailing
1119 MEDLIN STREET, SMYRNA, GA 30080
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
11
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
May 16, 2019
Penalty
Initial $3,031 · Current $1,819 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles.    (a) New townhome construction located on Lots #70-76, Top plate: On or about 01/15/2019, and at times prior, the employer exposed employees to struck-by hazards while operating pneumatic framing nail guns, in that protective eyewear was not provided to employees using these tools at 120 PSI while engaged in roof truss framing.
Recent events (2)
  • — I (S) $1818.6
  • — Z (S) $3031

1926.501 B13

Serious Gravity 10 3 instances 3 exposed
Issued
May 16, 2019
Penalty
Initial $5,304 · Current $3,182 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     (a) New townhome construction located on Lot #74, #75, and #76, Top plates: On or about 01/15/2019, and at times prior, the employer exposed employees to fall hazards of approximately 39-feet to the lower level, in that a fall protection system was not provided to employees engaged in roof framing activities on the top plate.     (b) New townhome construction located on Lot #75, Rear side, third level balcony: On or about 01/15/2019, and at times prior, the employer exposed employees to fall hazards of approximately 30-feet to the lower level, in that a fall protection system was not provided to and employee handing materials up to employees installing roof trusses.     (c) New townhome construction located on Lot #75, Front side, third level: On or about 01/15/2019, and at times prior, the employer exposed employees to falls of approximately 30-feet to the lower level, in that a fall protection system was not provided to the employee removing sheathing from the all-terrain forklift truck.
Recent events (2)
  • — I (S) $3182.4
  • — Z (S) $5304

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
May 16, 2019
Penalty
Initial $3,031 · Current $1,819 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    (a) New townhome construction located on Lot #76, Back second floor window: On or about 01/15/2019, and at times prior, the employer exposed employees to falls of 13-feet, 9-inches to the lower ground level, in that the ladder used to access the lower level was not extended at least 3-feet to allow safe access to the lower level.
Recent events (2)
  • — I (S) $1818.6
  • — Z (S) $3031

1926.403 B01

Other-than-serious 1 instance 2 exposed
Issued
May 16, 2019
Abate by
May 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:  (a) New townhome construction located on Lot #76, Rear side: On or about 01/15/2019, and at times prior, the employer failed to inspect all of the electrical cords prior to the start of the work shift. Two 50-ft. flexible cords used to power both air compressors on site were missing the ground pins as these cords were not repaired or removed from service.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Fermin Garcia's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343716130.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.