WILMINGTON, DE —
OSHA Inspection: INDUSTRIAL SERVICES GROUP, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of INDUSTRIAL SERVICES GROUP, INC. in 1000 FERRY ROAD, WILMINGTON, DE 19801 (NAICS 238320). OSHA activity number 343730651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDUSTRIAL SERVICES GROUP, INC.
- Site address
- 1000 FERRY ROAD
- City
- WILMINGTON
- State
- DE
- ZIP
- 19801
- Mailing
- 318 NEELEY STREET, SUMTER, SC 29150
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 287
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 8, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $9,472 · Current $6,981 Reduced
General-duty citation text
29 C.F.R. 1910.134(e)(1) � The employer did not provide a medical evaluation to determine the employee�s ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer did not ensure that the medical evaluation of some employees who were required to wear elastomeric respirators while engaged in spraying operations had been completed within the preceding year.
Recent events (3)
- — J (S) $6980.8
- — C (S) $9472
- — Z (S) $9472
1910.134 F01
- Issued
- Jul 8, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $5,683 · Current $6,981
General-duty citation text
29 C.F.R. 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT). a) 1000 Ferry Road, Wilmington, DE: On or about January 9, 2019, the employer did not ensure that some employees required to wear elastomeric respirators while engaged in spraying operations had completed a fit test within the preceding one year period.
Recent events (3)
- — J (S) $6980.8
- — C (S) $5683
- — Z (S) $5683
1926.102 A01
- Issued
- Jul 8, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $9,472 · Current $6,931 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer failed to provide goggles and face shields to employees exposed to liquid chemicals while engaged in tank spraying operations.
Recent events (3)
- — J (O) $6930.8
- — C (S) $9472
- — Z (S) $9472
1926.1204 E01 II
- Issued
- Jul 8, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $13,260 · Current $6,931 Reduced
General-duty citation text
29 CFR 1926.1204(e)(1)(ii): (ii) When entry is authorized, the employer did not continuously monitor entry conditions in the areas where authorized entrants are working, except that employers may use periodic monitoring in accordance with paragraph (e)(2) of this section for monitoring an atmospheric hazard if they can demonstrate that equipment for continuously monitoring that hazard is not commercially available; a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer failed to continuously monitor conditions where employees were working in the juice tank that was classified as a permit required confined space.
Recent events (3)
- — J (O) $6930.8
- — C (S) $13260
- — Z (S) $13260
1926.1204 I
- Issued
- Jul 8, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1204(i): 29 CFR 1926.1204(i): The employer did not develop and implement procedures for summoning rescue and emergency services (including procedures for summoning emergency assistance in the event of a failed non-entry rescue), for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue: a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019 the employer failed to implement rescue procedures for employees working inside a juice tank that was classified as a permit required confined space.
Recent events (3)
- — J (S) $0
- — C (S) $13260
- — Z (S) $13260
1926.1206 D
- Issued
- Jul 8, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1206(d): (d) The employer did not identify the authorized entrants within the permit space, by name or by such other means (for example, through the use of rosters or tracking systems) as will enable the attendant to determine quickly and accurately, for the duration of the permit, which authorized entrants are inside the permit space; a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer failed to identify all entrants on the confined space permit.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1926.1206 G
- Issued
- Jul 8, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1206(g): (g) The employer did not identify the individual, by name, currently serving as entry supervisor, and the signature or initials of each entry supervisor who authorizes entry; a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer failed to identify the entry supervisor on the permit required confined space entry permit.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1926.1206 N
- Issued
- Jul 8, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1206(n): The employer did not identify on the permit the equipment, such as personal protective equipment, testing equipment, communications equipment, alarm systems, and rescue equipment, to be provided for compliance with this standard; a) 1000 Ferry Road, Wilmington, Delaware: On or about January 9, 2019, the employer failed to identify required personal protective equipment on the permit required confined space entry permit.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Industrial Services Group, INC.
View Industrial Services Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238320)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343730651.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.