Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: NORTH AMERICAN LIGHTING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORTH AMERICAN LIGHTING, INC. in 2277 S. MAIN ST., PARIS, IL 61944 (NAICS 336399). OSHA activity number 343737136.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch North American Lighting, INC. for free Get an email when a new federal OSHA severe-injury report for North American Lighting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2277 S. MAIN ST.
City
PARIS
State
IL
ZIP
61944
Mailing
2277 S. MAIN ST., PARIS, IL 61944
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
300
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 8, 2019
Penalty
Initial $9,472 · Current $6,630 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:       On or about January 24, 2019, employees were exposed to amputation hazards when performing maintenance and servicing on equipment, including but not limited to, the LED Attachment Machine, because the employer did not conduct an annual inspection of the machine specific procedures, to ensure the procedures and requirements of this standard were followed.
Recent events (2)
  • · I (S) $6630.4
  • · Z (S) $9472

1910.147 C06 II

Serious Gravity 5 1 instance 3 exposed
Issued
May 8, 2019
Abate by
Jun 7, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:     On or about January 24, 2019, employees were exposed to amputation hazards when performing maintenance and servicing on equipment and the employer did not certify periodic inspection had been performed.  The certification shall include identification of the machine or equipment, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 D

Serious Gravity 5 1 instance 3 exposed
Issued
May 8, 2019
Abate by
Jun 7, 2019
Penalty
Initial $9,472 · Current $6,630 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):      Employees who performed servicing and maintenance on the LED Attachment Machine were not required to:   (1)   Know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy,    (2)   Turn off and shut down the machine,    (3)   Physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source,   (4)   Affix lockout or tagout devices to each energy isolating device,   (5)   Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished.       On or about January 16, 2019,  an employee was exposed to hazardous energy sources when performing maintenance and servicing on the LED Attachment Machine because the employer did not did not cover the action listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6).
Recent events (2)
  • · I (S) $6630.4
  • · Z (S) $9472

View North American Lighting, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343737136.