Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRO-TECH PLUMBING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRO-TECH PLUMBING, INC. in SCHILT AVENUE (NORTH OF EDSON) MCAS MIRAMAR, SAN DIEGO, CA 92145 (NAICS 238220). OSHA activity number 343738308.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pro-Tech Plumbing, INC. — free Get an email when a new federal OSHA severe-injury report for Pro-Tech Plumbing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
SCHILT AVENUE (NORTH OF EDSON) MCAS MIRAMAR
City
SAN DIEGO
State
CA
ZIP
92145
Mailing
P.O. BOX 279, RAMONA, CA 92065
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
May 28, 2019
Abate by
Jun 7, 2019
Penalty
Initial $3,580 · Current $1,790 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the unintentional release of pressure while installing a water pipeline:  Reclaimed Water Project at Schilt Avenue and Edson Street, MCAS Miramar: On January 2, 2019, employee(s) were extending a water pipeline in a trench without de-pressurizing the system prior to removing the pipe cap.  An employee was exposed to struck-by hazards when up to 80 psi of pressure unintentionally released and the 12-inch diameter iron cap struck him, resulting in hospitalization for his injuries.
Recent events (2)
  • — I (S) $1790
  • — Z (S) $3580

View Pro-Tech Plumbing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343738308.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.